How to maintain the lubrication system of water-cooled chillers
Medium-sized water cooled chiller,
refrigeration temperature range from -80 ℃~ -30℃, safe,
reliable, rapid cooling for the liquid, widely used in petrochemical, medical,
pharmaceutical, biochemical and freeze-dried, military and other high-tech industries.

When the water cooled chiller is below 80℃ ~ 30℃ below zero
in the running system, people pay more attention to refrigerator, frozen water
cycle system and electric control system, so the lubrication system is often
overlooked. However, this system is also very important to the water cooled
chiller. The maintenance of the water cooled chiller is indispensable, now we
are going to tell you something about it.
1. Observe the normal oil surface, oil
temperature and oil pressure in the daily inspection.
2. Regularly check the oil quality
according to the oil change index stipulated in the frozen lubricating oil, and
replace or supplement the filtered new oil.
3. Pay attention to check and adjust the
end face clearance of the oil pump in the middle and overhaul, and replace the
pump when necessary. The end face clearance of the pump varies from 0.03 to
0.08mm. Please refer to the assembly technical requirements and factory
regulations of the pump for concrete value.
4. Regularly replace or clean the filter
core, pipeline, and crankcase.
The maintenance of the lubrication system
of the water cooled chiller requires techniques, which mainly involves the
performance of the compressor’s main engine. It is recommended to be operated
by professionals to avoid unnecessary losses.
If you are purchasing our LNEYA
water-cooled chiller, you can contact our after-sales team. If you have
purchase needs or questions in this regard, you can also contact our team
sales@lneya.com, we will reply to you as soon as possible.
Похожие рекомендации
-
На что следует обратить внимание при выборе промышленных тепловых и холодильных машин
2075In food factories, pharmaceutical factories, biology, new material processing, and chemical plants, the raw materials in the reactor need to be cooled rapidly during the industrial production process involved in the reactor. In order to achieve th...
Посмотреть детали -
Routine maintenance points of special refrigeration units for laboratory instruments
2255Industrial refrigeration units dedicated to laboratory instruments are used more in the pharmaceutical and chemical industries, and care must be taken when using them. The daily maintenance of the industrial refrigeration unit dedicated to experim...
Посмотреть детали -
Ультранизкотемпературный водяной охладитель 60P потребляет слишком много энергии и требует внимания
1744Ультранизкотемпературные водяные охладители 60p разных производителей имеют разные конфигурации производительности и разное энергопотребление. Если вы обнаружите, что потребление энергии слишком велико, необходимо вовремя проверить, нет ли в этом проблемы...
Посмотреть детали -
How To Choose The Equipment For The Reactor?
1655The choice of equipment for the reactor needs to be measured by the following points: 1. Heating method: Generally, the electric heating should be greater than or equal to 3 tons, and in the case of the outer half pipe; less than or equal to 3 ton...
Посмотреть детали
工業冷水機製造商 LNEYA Taiwan