Специфические условия испытания батареи EV (электромобиля) при высоких и низких температурах
There are mainly 2 types of vehicles:
1. Battery for pure electric vehicle
2. Fuel cell, dedicated to fuel cell electric vehicles
Thermal test: This test is performed to characterize the reaction of cells to the high-temperature environment.
a) Adjust the SOC of battery to 100% of BEV application and 80% of HEV application.
b) Batteries stabilized at room temperature shall be placed in a gravity or circulating air convection oven. The oven temperature shall be raised to 130 ℃ ± 2K at the speed of 5K/min. The battery shall be held at this temperature for 30 minutes before stopping the test.
Temperature Cycle Test:
This test is conducted to characterize the thermal durability of the battery by alternately exposing it to low and high temperatures to cause expansion and contraction of the battery components.
a) Adjust the SOC of battery to 100% of BEV application and 80% of HEV application.
b) Conduct temperature cycling according to ISO 16750-4. As shown in Table 4, the ultra-low operating temperature shall be – 40 ℃ or Tmin specified by the battery manufacturer, and the maximum operating temperature shall be 85 ℃ or Tmax specified by the battery manufacturer. Perform 30 test cycles as specified.
The battery shall be heated in a gravity convection or circulating air oven with an initial temperature of 20 ± 5 ° C (68 ± 9 ° F). The temperature of the oven is raised to 130 ± 2 ℃ (266 ± 3.6 ℉) at the rate of 5 ± 2 ℃ (9 ± 3.6 ℉) per minute and maintained for 10 minutes. The sample shall be returned to room temperature (20 ± 5 ℃) and then checked. For batteries with a set temperature higher than 100 ℃ (212 ℉), the regulating temperature shall be increased from 130 ± 2 ℃ (266 ± 3.6 ℉) to 30 ± 2 ℃ (86 ± 3.6 ℉) from the manufacturer’s maximum specified temperature. For lithium metal chemical battery, the regulating temperature shall be increased to 170 ± 2 ℃ (338 ± 3.6 ℉) at most.
The above contents are excerpts from the network. Please contact us if you have any questions.
Похожие рекомендации
-
How to maintain the lubrication system of water-cooled chillers
1887Medium-sized water cooled chiller, refrigeration temperature range from -80 ℃~ -30℃, safe, reliable, rapid cooling for the liquid, widely used in petrochemical, medical, pharmaceutical, biochemical and freeze-dried, military and other high-tech in...
Посмотреть детали -
Метод соединения реакционного чайника и электрического шкафа управления реакционным оборудованием
1972Вспомогательным оборудованием реакционного чайника является продукт контроля температуры, предоставляемый нашей компанией для большинства пользователей. Когда пользователь выбирает оборудование для реакционного чайника, необходимо понимать, что...
Посмотреть детали -
Отказ компрессора системы управления охлаждением из-за давления масла
1947Если в системе управления холодильным оборудованием отсутствует давление масла, проверьте соединение трубопровода масляного насоса на предмет утечки или засорения. Если соединение ослаблено, его следует затянуть. Если оно заблокировано, следует прочистить масляный трубопровод...
Посмотреть детали -
Failure Analysis of Ultra Low Temperature Chiller Supporting Distillation Equipment
2479Once the freezer used in the matching distillation equipment fails, we need to solve it in a timely and effective manner to avoid affecting the operation of the entire experiment. In the pharmaceutical, chemical and other industries, low temperatu...
Посмотреть детали
工業冷水機製造商 LNEYA Taiwan