How to avoid improper operation of heating and cooling circulator?
When the user runs the heating and cooling circulator, the operation needs to follow the instructions. Then, how to avoid unsuitable operation?
LNEYA heating and cooling circulator has multi-function alarm system and safety function. It uses plate heat exchanger and pipeline heater to increase heating and cooling rate. Large-screen touch screen graphic display, heating and cooling machine uses magnetic drive pump, no shaft seal leakage problem. Fully enclosed system, extending the life of the thermal fluid, a very wide temperature range, without the need to change the liquid medium.
Before the heating and cooling circulator is turned on, the inlet valve of the condenser on the unit that does not need to be opened is turned off to cause drowning, and a part of the cooling back water flows away from the condenser of the starting group, thereby reducing the cooling water in the condenser of the running unit. The flow rate causes the condensing pressure to rise. The operating current of the main unit increases. The cooling capacity of the unit is reduced, and the unit will be shut down seriously. It wastes electricity and reduces the cooling effect, and it is also easy to damage the equipment.
Due to the previous misoperation, the condensing pressure of the main engine and the temperature of the cooling water effluent rise, causing misjudgment to the operator. It is mistaken that the cooling water is not enough to open the condenser inlet valve and the cooling water pump outlet valve, and some also increase the cooling tower fan, resulting in increased power consumption of the pump and cooling tower fan. In addition, some users blindly added a cooling water pump. Although the addition of the cooling water pump can indeed reduce the cooling water temperature and the condensing pressure, after all, the power of one pump is wasted, so it is wrong.
The correct operation method of the heating and cooling circulator is that the unit condenser inlet valve is not required to be closed before starting to prevent drowning. Opening the heating and cooling unit will run the inlet and outlet valves on the unit condenser (the general outlet valve is normally open, the inlet valve is opened and closed as needed, and the condenser and evaporator are the same) to open the corresponding cooling water pump. Adjust the inlet and outlet pressure of the condenser to about 68.6 kPa (0.7 kg/cm). If the condenser inlet and outlet pressure gauges are swung too far, the cooling water system has air. The air should be vented until the pressure gauge indicates normal and continue to the next step.
During the use, do not handle all kinds of faults yourself, and avoid secondary damage caused by improper handling.
Verwandte Empfehlungen
-
Vorsichtsmaßnahmen für das Kühlsystem der Kältemaschine bei Niedrigtemperaturbetriebstest
2331Es gibt gewisse Unterschiede in der Verwendungsmethode, der Funktion, dem Aufbau usw. der verschiedenen Arten von Kältesystemen für Tieftemperaturbetriebstests. Die Kältemaschine des industriellen Niedertemperaturbetriebstests erfordert die Erzeugung von Wärme...
Details anzeigen -
API exhibition LNEYA is brilliant
2289On October 14, 2020, the 85th China International Pharmaceutical Raw Materials/Intermediates/Packaging/Equipment Fair (API China for short) was grandly opened at Nanjing International Expo Center. The exhibition site was bustling and popular. LNEY...
Details anzeigen -
Was ist die Funktion eines Hochtemperatur-Wärmeübertragungssystems??
1911Das Hochtemperatur-Wärmeträgerflüssigkeitssystem verfügt über ein vollständig geschlossenes Zirkulationssystem, so dass während des Hochtemperaturbetriebs kein Ölnebel entsteht und eine Hochtemperaturkühlung realisiert werden kann. Es ist die Temperaturregelung Ausrüstung u...
Details anzeigen -
Markentipps für Gefriergeräte mit ultraniedriger Temperatur
1757Wenn es um Ultratiefkühlgeräte geht, sind die meisten Menschen besorgt, weil die ultraniedrigen Temperaturen eine größere Herausforderung für die Technik darstellen. Im Vergleich zu anderen Kältemittelanlagen, die Entscheidungen der ultratiefen Temperatur Gefrierschrank...
Details anzeigen
工業冷水機製造商 LNEYA Taiwan