Wie wählt man die Kältemaschine zur Kühlung des Mischtanks aus?
Mixing tanks are used in coatings, medicine, building materials, chemicals, pigments, resins, food, scientific research and other industries to stir, mix, blend, and homogenize materials. The mixing tank will generate heat during the mixing process, what cooling is used for the mixing tank? The chiller is a device that can maintain constant temperature, constant temperature and constant flow. Cooling the medium with a stirred tank can help.
1. When the mixing tank needs a temperature range of 5 degrees to 30 degrees, use a high-temperature chiller to cool down the mixing tank. When adding ethylene glycol solution to the high-temperature chiller, the temperature can be -5 degrees.
2. When the mixing tank needs to be controlled within the temperature range of -5 degrees to -35 degrees, a medium temperature chiller is used to cool down the mixing tank. The medium-temperature chiller can use ethylene glycol or brine as the refrigerant. When using brine as the refrigerant, the evaporator needs to be anti-corrosion designed.
3. When the mixing tank needs to be controlled in the temperature range of -40 degrees to -120 degrees, a low-temperature chiller is used to cool down the mixing tank.
Depending on the material requirements of the mixing tank, some of them need to be heated. At this time, a cold and hot water chiller can be used. This is a temperature control device that can both cool down and raise the temperature. The temperature control range is from -120 degrees to 200 degrees.
If the mixing tank is used in an environment containing explosive gas, use an explosion-proof chiller to cool down the mixing tank.
Some of the materials in the mixing tank need to be heated, dried or cooled. The cooling cycle uses water to circulate inside and outside the jacket so that the materials will not form agglomerates or stickiness at a certain temperature. It can also be heated or cooled by adding coils and other forms according to user requirements.
If there are technical requirements for the cooling of the mixing tank, it can be customized according to the actual requirements. Please contact us. LNEYA is a manufacturer with exclusive technology and independent research and development and production of industrial temperature control equipment such as chillers.
Verwandte Empfehlungen
-
Precautions for the use of molecular distillation cooling and heating temperature control
1839The SUNDI series of LNEYA refrigeration and heating temperature control system are used together to control the temperature in the process of molecular distillation. What should be paid attention to in use? If the molecular distillation method ca...
Details anzeigen -
Daily maintenance method of heat transfer oil cooling and heating cycle machine
2240The heat-conducting oil cooling and heating cycle machine is a supporting set of various reactors in the pharmaceutical and chemical industry. The reactor can be used for cooling or heating, and has a high energy efficiency ratio. It does not requ...
Details anzeigen -
Beschreibung der Typenauswahl und Klassifizierung von 40-GW-Kaltwassersätzen
1999Wenn verschiedene Unternehmen und verschiedene Branchen unterschiedliche Anforderungen an Wuxi Guanya 40GW kryogenen Kältemaschinen haben, ist seine Modellauswahl auch unterschiedlich. So ist es besser, ein klares Verständnis der Bedürfnisse der Auswahl der 40GW kryog...
Details anzeigen -
Entladungsvorgänge von Industriekühlern in Ammoniak-Kältesystemen
2027Der Gummischlauch, der zum Anschluss des Auslassventils verwendet wird, wird mit einem Ende in das Wasser des Wasserbehälters eingeführt. Wenn das Ammoniak im Mischgas zu Ammoniakflüssigkeit abgekühlt ist, gefriert der Boden des Luftabscheiders. Zu diesem Zeitpunkt, ...
Details anzeigen
工業冷水機製造商 LNEYA Taiwan