Analyse der Ursachen des Lärms, der durch den Betrieb von Niedertemperaturkältemaschinen entsteht
Noise is common in the operation of industrial equipment. There are many reasons for noise, which may be caused by some environmental problems in the installation. When noise is generated, we must first confirm the cause and whether it is an internal component. The problem is raised because if a problem occurs and the replacement or repair is not stopped in time, the low temperature chiller will not work properly.
The environment and location of the device can cause noise problems, and if it is in a relatively small environment, the noise will be “amplified”. A smaller environment will make the normal operation sound louder and will sound out of normal operation. It is recommended that both air-cooled and water-cooled units be installed in a relatively open environment with no foreign objects around them. If the requirements are higher, the soundproof wall can be installed and ventilation and heat dissipation can be observed.
There is no flatness processing under the device position, which will result in displacement during normal operation, as well as vibration and shaking during normal operation. Under displacement conditions, the amplitude of the vibration will increase and a large amount of noise will be generated.
Due to the operational noise caused by the low temperature chiller itself, air coolers and water coolers are more prone to “noise” than the latter due to structural differences. It is well known that air-cooled chillers are cooled by a fan for the condenser, while the water cooler is cooled by a cold water tower system for the condenser. Compared to the noise of the cold water tower (usually placed at a high position, it is different from the position of the water cooler). The fan is noisy and integrated with the chiller main unit, so it is easier to feel the noise (can remove the blades or fill the bearings with smooth oil).
In addition, the compressor of a low temperature chiller is one of the sources of noise. The selected compressor can have low noise characteristics and the chiller noise must be low. Otherwise, the overall chiller will be noisy.
In addition to the noise figures of the chillers used in low-temperature chillers, whether it can be operated continuously for a long time, whether to add appropriate smooth oil, whether it can be regularly maintained, and whether the service life is too long is the key to balancing the noise elements of low-temperature chillers. Where. In addition, there are pumps for both air and water cooling. If the pump is running too loud, it may need to be cleaned.
Then, as an important part of the Niedertemperaturkühler, in order to reduce losses and generate noise, we should always maintain to extend its service life and improve operational efficiency:
1. Check if the oil level of the fuselage and oiler is normal.
2. Check the movement flexibility of the oiler and the amount of oil injected
3. Check the oil leakage, water leakage and air leakage of the compactor and take corresponding measures to remove it.
4. Check that each valve is open.
5. Check that the vibration of the machine is normal. Otherwise, it is necessary to stop the inspection and scanning.
6. Check that the value of each meter is normal.
7. Check the smooth oil process (fine) filter and replace the fine filter according to the conditions. Stop cleaning the strainer.
If you have any knowledge of the use, maintenance, equipment prices, etc. of cryogenic chillers, please contact LNEYA and discuss: sales@lneya.com/LNEYA.COM.
Verwandte Empfehlungen
-
Function of Evaporator in Air Cooled Chiller
1935The air-cooled chiller adopts the air cooling mode, which eliminates the essential cooling tower, cooling water pump and pipeline system of the cooling water system, avoids the condenser scaling and water pipe blockage in areas with poor water qua...
Details anzeigen -
Wie schützt man einen Kühlschrank mit einer Temperatur von null bis 86 Grad?
2129The structure of the scroll compressor and the piston compressor in the low-to-86 degree low-temperature refrigerator is different, and it cannot be reversed. The reverse phase of the three-phase power supply of the low-zero-86 degree low-temperat...
Details anzeigen -
Application and working principle of water-cooled chiller
1897Application and working principle of water-cooled chiller The water-cooled chiller is a kind of LNEYA industrial low-temperature refrigerator in Wuxi Guanya. A single compressor can achieve -152 degrees Celsius cooling and cooling. Equipment powe...
Details anzeigen -
Where do you need low temperature chiller and introduction
1764Even though water is one of the most precious and scarce resources, it is still used as a coolant in many laboratories. Unfortunately, most of the water used as a coolant is not recycled, resulting in higher and higher laboratory costs and wasted ...
Details anzeigen
工業冷水機製造商 LNEYA Taiwan