Einbauorte von Kryopumpen in Tiefkühlschränken
Beim Bau eines Tiefkühlgeräts ist die Kryopumpe ein Muss. Der Hersteller von Tiefkühlgeräten LNEYA weist darauf hin, dass die Kryopumpe bei der Installation entsprechend den Anforderungen betrieben werden sollte. Installationsmöglichkeiten...
Installation facilities and requirements:
The foreline pump—the cryopump requires a pre-stage pump pre-vacuum chamber to draw the start-up pressure of the cryopump and to remove the gas generated during regeneration when the cryopump is regenerated.
Adsorption well—Install the water-cooled baffle. If the oil vapor returns to the cryopump, the low-temperature freezer tells you that if its adsorption array is contaminated, the adsorption array must be replaced.
High vacuum valve—installed between the cryopump and the vacuum chamber, which can shorten the start-up time, regenerate the cryopump without deflation in the vacuum chamber, and leak the vacuum chamber at any time.
Pre-pumping valve—At the pre-pumping port of the cryopump, a valve must be installed. The valve is open during pre-extraction and regeneration, and is closed during operation of the cryopump. Another one is used for The same mechanical pump pre-extracts the vacuum chamber.
Installation of compressor:
Make sure the compressor is placed on a stable level.
Static pressure – turn off the compressor and let it be at room temperature. The pressure should be between 1.4-1.5 Mpa. If the pressure indication is low, you need to add some He gas (99.999% purity).
The cooling water pipe connected to the compressor is connected to the water-cooled compressor.
Install the cryopump:
High vacuum flange connection
The cryostat Xiaobian tells you that the cryopump can be fixed in any place required by the vacuum chamber by means of its high vacuum flange. Please check whether the “O” ring is intact before installation, and the surface is free of indentation and debris. .
Connection of the suction port and the safety valve
The cryopump cannot be vented during operation, so it is necessary to pre-pump the cryopump through the suction port by using a rough pump such as a mechanical pump before starting, and it can be used as an outlet for the gas released during regeneration. Be sure to connect the pumping port of the cryopump to the pre-stage pump of the corresponding size.
Connect the cryopump and compressor
Remove the cryopump and compressor, as well as the protective caps on all self-sealing joints on the metal hose.
Note: Never use a cleaner to wipe the self-sealing joint in the following steps.
Before connecting, you must ensure that there are no dust, oil, particles, etc. on the joint. If necessary, use a brush to clean the thread. Use a soft cloth without cotton to wipe any dirt on the sealing surface.
Connect the metal hose, connect the hose according to the direction of the airflow, start from the compressor to the cryopump, then from the cryopump to the compressor, use two wrenches to tighten each self-sealing joint to protect the hose from twisting and leaking. , moderately tighten each joint. The low-temperature freezer, which is good, tells everyone that after the connection is completed, the indication of the pressure gauge of the compressor is checked. If it is 1.3 to 1.5 MPa, it is normal. If it is lower than this value, the purity is greater than 99.999% as described above. Add some more to your suffocation.
Special Note: The metal hose maintains a high pressure of 1.4-1.5 MPa, so it should be used with great care to prevent damage or reverse.
Verwandte Empfehlungen
-
What Are the Features of the Glycol Refrigeration System
2037The difference between the glycol refrigeration system and the general refrigeration system is that the glycol solution is used as refrigerant to run the refrigeration system. The glycol refrigeration system is widely used. It can be used in many ...
Details anzeigen -
Fehlerbehebungsschritte bei industriellen Wasserkühlmaschinen in der chemischen Industrie
2023Nach Abschluss der Installation von industriellen Kaltwassersätzen in Chemieunternehmen müssen in der Anfangsphase des Betriebs bestimmte Fehlerbehebungen durchgeführt werden. Nur durch eine sorgfältige Fehlersuche können wir herausfinden, ob es versteckte Probleme in...
Details anzeigen -
Electric Vehicle Motor Test Cooling System Chiller Instructions
2525With the continuous development of new energy vehicles, Chiller, the electric motor motor test cooling system, is also developing. The new chiller for motor testing of new energy vehicles can adaptively adjust the chiller according to the dynamic ...
Details anzeigen -
Wie wählt man die Kältemaschine zur Kühlung des Mischtanks aus?
2421Mischbehälter werden in den Bereichen Beschichtungen, Medizin, Baustoffe, Chemikalien, Pigmente, Harze, Lebensmittel, wissenschaftliche Forschung und anderen Branchen zum Rühren, Mischen, Vermengen und Homogenisieren von Materialien verwendet. Der Mischbehälter erzeugt während des Mischvorgangs Wärme...
Details anzeigen
工業冷水機製造商 LNEYA Taiwan