Detaillierte Einführung von luftgekühlten Kältemaschinen

LNEYA refrigeration has accumulated over 10
years of cooling supporting application experience. According to different
application fields and service conditions, it has developed a variety of types
of cooling chillers, including air cooled chillers and water cooled chillers,
which can well meet the needs of equipment cooling. The heat dissipation device
of air cooled chiller is a built-in fan, which mainly has three interrelated
systems: refrigerant circulation system, water circulation system and electrical
automatic control system.
1. Refrigerant circulation system: the
liquid refrigerant in the evaporator absorbs the heat in the water and begins
to evaporate. Then, a certain temperature difference is formed between the
refrigerant and the water. After the liquid refrigerant is completely
evaporated and becomes gaseous, it is inhaled and compressed by the compressor
(pressure and temperature increase). The gaseous refrigerant absorbs heat
through the condenser and condenses into liquid. After throttling through the
expansion valve, the low-temperature and low-pressure refrigerant enters the
evaporator to complete the refrigerant circulation process.
2. Water circulation system: the water pump
is responsible for pumping water from the water tank to the equipment that
needs to be cooled. After the heat is taken away by the chilled water, the
temperature rises, and then returns to the chilled water tank.
3. Electrical automatic control system:
including power supply part and automatic control part. The power supply part
supplies power to the compressor, fan, water pump, etc. through the contactor.
The automatic control part includes temperature controller, pressure protector,
time delayer, relay, overload protector, etc. combined with each other to
achieve the functions of automatic opening or suspension and other protection
according to the temperature requirements.
Our air cooled chillers can be widely used
in medical, biological, chemical, laser, metallurgy, equipment manufacturing,
electroplating, plastic processing and other industries. Please consult us for
details.
Verwandte Empfehlungen
-
Common faults of plate heat exchangers in new energy vehicle inspection
2580The reason for the excessive pressure drop of the new energy vehicle detection is that the running system pipeline is not properly purged, especially in the newly installed system pipeline, many dirt (such as welding slag) enters the interior of t...
Details anzeigen -
What are the advantages and disadvantages of thermal oil heating circulators?
2187The heat conduction oil heating circulator adopts a fully closed loop structure to directly act on the heat energy to the heated medium. Its advantages are: (1) Due to the continuous renewal of the heat transfer surface, the heat loss is small; (...
Details anzeigen -
Wie wird die Temperatur bei der Lösungsmittelrückgewinnung durch Destillation geregelt?
19781. Wenn die Produktqualität durch das Vorhandensein von Luft bei einer höheren Temperatur nicht beeinträchtigt wird, kann sie zunächst bei Normaldruck gewonnen werden, und wenn die Temperatur den Normaldruck-Siedepunkt des Lösemittels um 10 Grad übersteigt, wenn die...
Details anzeigen -
Annäherung an LNEYA 5 Hauptprodukte
3304Industrial Chiller:Industrial Chiller varies from dynamic temp. control systems, heating and cooling machine, water/air cooled chiller and heating circulator.Dynamic temp. control systems.All the industrial chiller differ sometimes considerably i...
Details anzeigen
工業冷水機製造商 LNEYA Taiwan