Worauf sollte ich bei der Auswahl eines Verdampfers für eine Ultra-Niedertemperatur-Kältemaschine achten?
The evaporator in the ultra-low temperature chiller is one of its four major components, so performance is more important.
The selection of ultra-low temperature chillers needs to pay attention to the influence of liquid level on the evaporation temperature. Due to the influence of the height of the refrigerant liquid column, the evaporation temperature at the bottom of the flooded evaporator is higher than the evaporation temperature of the liquid surface. The evaporation temperature of different refrigerants at different liquid levels is affected differently by the height of the static liquid. Regardless of the refrigerant, the lower the evaporation temperature of the liquid surface, the greater the influence of the hydrostatic height on the evaporation temperature. Therefore, only when the evaporation pressure is high, the influence of the hydrostatic height on the evaporation temperature can be ignored. When the evaporation temperature is low, it cannot be ignored. In other words, it becomes uneconomical to use a flooded evaporator at this time.
If the evaporation temperature is lower than the freezing temperature of the refrigerant, the refrigerant may freeze. In the subsequent flow of the refrigerant, the temperature of the refrigerant is low, and the possibility of freezing is high. When water is used as the refrigerant, theoretically, the temperature of the inner wall of the tube can be as low as 0°C. However, for safety reasons, the temperature of the inner wall of the pipe at the outlet end of the next process is usually kept above 0.5°C. In the case of brine as the refrigerant, according to the same principle, the temperature of the inner wall of the tube should be higher than the freezing temperature of the refrigerant by more than 1°C.
When the refrigerant flows through the evaporator, pressure loss is caused, which will inevitably make the pressure p2 of the refrigerant at the outlet of the evaporator be lower than the pressure p1 at the inlet, thereby reducing the suction pressure of the compressor, resulting in a decline in the refrigeration capacity.
According to different models, the choice of evaporator is different. For example, the box-type small ultra-low temperature chiller uses a water tank coil type evaporator; the open-type small ultra-low temperature chiller and the screw-type small ultra-low temperature chiller use shell and tube Type evaporator; for acid and alkali resistant ultra-low temperature chillers, you can choose titanium tube evaporator or stainless steel plate exchanger; there are many options, of course, it can be customized according to user needs.
The ultra-low temperature chiller evaporator is generally designed and equipped by the ultra-low temperature freezing test manufacturer. It is recommended that users check the configuration problems when choosing the ultra-low temperature chiller manufacturer.
Verwandte Empfehlungen
-
Flüssigkeitsgekühltes Akkupack BMS-Test Kühlwasserzirkulator
2321Da die Temperatur allmählich ansteigt, erreicht auch der Einsatz des Kühlwasserumwälzers für den BMS-Test des flüssigkeitsgekühlten Batteriesatzes allmählich einen Spitzenwert. Die Nennleistung des Kühlwasserumwälzers für die BMS-Prüfung von flüssigkeitsgekühlten Batteriepacks...
Details anzeigen -
2019 CPHl China | LNEYA W5P22 Ausstellungsgelände&Wunderbar
1992Vom 18. bis 20. Juni 2019 fand die 19. Weltausstellung für pharmazeutische Rohstoffe China - CPhI China 2019 im Shanghai New International Expo Center statt. LNEYA war mit einer Vielzahl von Geräten auf dem Stand W5P22 vertreten, der drei Tage lang ...
Details anzeigen -
The selection and maintenance of ultra-low temperature chiller
1722Today, a customer came to inquire about our need for a small laboratory water chiller. The specific working condition is to reduce the materials in the 20L stainless steel reactor from normal temperature to minus 30 ℃ in more than one hour. This p...
Details anzeigen -
Explanation Protection for Air Cooled Precision Chiller
2017The places where need air-cooled precision chiller indicate they have high demanding for operating accuracy. Therefore, the protection settings have to work out. Then, which kind of protection for air-cooled precision chiller should be done? Disch...
Details anzeigen