Function of Water Pump of Industrial Water Chiller
The water pump is one of the important auxiliary components of the refrigeration system of the industrial water chiller. Many industries will use the industrial water chiller, but many people don’t know much about the equipment. This time, lneya refrigeration will talk about the role of the water pump of the industrial water chiller.
The function of the water pump of the industrial water chiller is to provide pressure and water flow according to the needs of the system. The chilled water pump is the water pump, also known as the circulating water pump. Of course, the chilled water pump is not only the water pump in the industrial water chiller system, but also may exist in the cooling water system of the air-cooled water chiller.
The water pump of industrial water chiller can determine the water flow of chilled water, that is, the water flow of chilled water is not only affected by the size and capacity of the water tank, but also affected by the chilled water pump. The water flow can determine the range of refrigeration temperature to some extent. When the same cooling capacity is transmitted with chilled water as refrigerant, the larger the water flow is, the higher the temperature of the cooling capacity will be.
Water flow is controlled by chilled water pump, so there is a close relationship between chilled water pump and industrial water chiller refrigeration. The specific reasons are as follows: while the water flow of the industrial water chiller increases, the cooling capacity of the chilled water per unit area will decrease. Although the total cooling capacity remains unchanged, the cooling capacity per unit area of the chilled water has decreased. Therefore, if the chilled water flow is large, the cooling effect will become worse and the temperature will become higher, However, this does not mean that the refrigeration capacity of the compressor and the whole chiller system becomes worse.
The chilled water system includes water pipeline, chilled water tank, water pump, etc. the specific parameter selection and xing’shi selection of the water pump are closely related to the model of the industrial chiller. Whether the type of the water pump and the parameter model can be selected will directly determine the refrigeration capacity of the industrial chiller and even whether the industrial chiller can work normally.
About the role of industrial water chiller water pump, that’s it. If you don’t understand, please consult us:sales@lneya.com!
Verwandte Empfehlungen
-
Sie sollten etwas über Tiefkühltruhen mit extrem niedriger Temperatur wissen
1592Der Ultratiefkühlschrank ist ein unverzichtbares kryogenes Lagerungsgerät im Bereich der Biowissenschaften und Biopharmazeutika. Er kann für die Lagerung von Zellen, Geweben, Testproben, Impfstoffen, aktiven Enzymen, Stämmen, Plasmiden, Viren und Bakterien verwendet werden...
Details anzeigen -
Is it right to extend battery life by lowering the ambient temperature?
1872The battery can work in a wide temperature range, but this does not allow the battery to be charged under high temperature conditions. The charging process is more delicate than the discharging process, and extreme care must be taken. Extreme cold...
Details anzeigen -
Temperature control instructions for stainless steel reactors and glass reactors
2288Reactor is a kind of reaction equipment in industrial production. It generally needs to be refrigerated or heated. Whether the temperature is suitable or not directly affects its reaction effect. Therefore, if conditions permit, it is generally e...
Details anzeigen -
The main purpose of the reactor heating and cooling system
2323The reaction kettle heating and cooling system is suitable for high-purity metals, rare substance purification, laboratory environment simulation, magnetron sputtering, vacuum coating and other industries. The large-scale cryogenic pump unit can p...
Details anzeigen