General high and low temperature integrated machine valve repair detailed description
The conventional high and low temperature integrated machine valve replaces the packing, and the main function of the packing is to prevent the working medium from leaking along the axial direction of the valve stem. In case of minor leakage, the packing gland can be tightened. If the leak cannot be eliminated, the packing should be replaced. When replacing, the valve stem must be screwed out to the end. Use the filler needle to pull out the old packing, then screw the prepared new packing in turn, and then tighten the gland.
In conventional high and low temperature integrated machine engineering, the valve core of a large diameter valve is sealed by a layer of babbitt or fluoroplastic. The back of the spool also has a layer of babbitt so that when the stem is rotated out of position, the working fluid can be sealed without leaking outward along the stem. After the valve is disassembled, first straighten the stem to deburr, then replace the valve’s babbitt alloy. At the same time, the valve seat should also be ground to make the valve core and the valve seat tight. For small cast steel or brass valve spools, the seal of this valve is obtained by a line of metal contact, hence the line seal. Because it is a wire seal, the valve seat and the valve core should be carefully ground to obtain a satisfactory sealing effect. After the valve is overhauled, the air tightness test shall be carried out in accordance with the relevant requirements.
The repair of the safety valve in the explosion-proof high-temperature integrated machine refrigeration system is also roughly the same as above, but since the babbitt alloy is soft, it is often difficult to return to the original position after the safety valve is operated once due to overpressure, so when the pressure is reduced to the closing pressure At the time, it is still not tight. In order to overcome this drawback, some products have changed the Babbitt alloy to a nickel-chromium-titanium (harder) alloy, or replaced with polytetrafluoroethylene.
The timely maintenance of conventional high and low temperature integrated machine valves can better help the operation of conventional high and low temperature integrated machines, so it is recommended to solve them in time.
Verwandte Empfehlungen
-
Der Hersteller erklärt, welche Einflüsse der Ölstand und der Ölunterschied der Kältemaschine haben?
2210The chiller manufacturer tells everyone that in addition to the refrigeration system, the lubricating oil system is also an important part, with its own oil reservoir and special oil cooler. Therefore, we must understand the influence of the oil l...
Details anzeigen -
Heißer und kalter schneller Temperaturwechsel in der Prüfkammer gemeinsamer Fehler
2016In der Hochtemperaturprüfung der heißen und kalten schnellen Temperaturänderung Prüfkammer, sobald die Temperaturänderung nicht den Testtemperaturwert erreicht, in diesem Fall kann das elektrische System überprüft werden und die Fehler können auf...
Details anzeigen -
Was sind die Merkmale des Reaktorheizsystems?
1550Wuxi Guanya LNEYA Reaktorheizsystem Der Flüssigkeitsumlauf des gesamten Systems ist geschlossen, das System hat ein Ausdehnungsgefäß, das Ausdehnungsgefäß und der Flüssigkeitsumlauf sind adiabatisch, nehmen nicht am Flüssigkeitsumlauf teil, nur die...
Details anzeigen -
Air-cooled and water-cooled methods of cooling and heating circulators
2148The cooling heating circulator is controlled by high and low temperature during operation. After the user runs at high temperature and low temperature, it can be heated with heat transfer oil, which is water-cooled and air-cooled. 1. It belongs ...
Details anzeigen
工業冷水機製造商 LNEYA Taiwan











