How to Choose Water Chiller Units in Small Factories
Professional water chiller factory said that the quality of equipment can be seen from the three main components of small water chiller units. The most important one is the compressor, which is the heart of the unit and the most critical component. A good compressor should not only run stably, but also ensure good energy efficiency.
Evaporator and condenser are also one of the main components of water chiller. Evaporator and condenser play the role of heat absorption and exothermic respectively. Adequate and appropriate heat transfer can give full play to the efficiency of compressor. If the heat transfer capacity of the condenser is insufficient, it will directly affect the refrigeration effect of the unit. In summer, the high pressure is easy to occur, and even the protection shutdown of the chiller is caused by the high pressure exceeding the standard. The heat transfer of evaporator is more important. The insufficient heat transfer will not only cause the inefficiency of the unit, but also make the refrigerant unable to evaporate completely. It will directly return to the compressor to cause liquid hammer and damage the compressor, thus making the whole chiller unusable.
Another main component is the expansion valve, which is not only a flow regulating valve but also a throttle valve in refrigeration equipment in the refrigeration system of water cooler. The main function is to reduce the pressure and throttle the refrigerant liquid flowing through the thermodynamic expansion valve at high pressure and normal temperature, and to change it into low temperature and low pressure refrigerant wet vapor, which enters the evaporator and vaporizes and absorbs heat in the evaporator, so as to achieve the purpose of refrigeration and cooling.
Small factories should pay attention to the following three points when choosing and purchasing:
1. Selection of key parts for chillers.
Compressor is the main index affecting the performance of shadow water chiller. In order to control the overall production cost, many water chiller manufacturers adopt poor quality products in compressor and other major parts, and even use retrofitted compressors, which seriously affects the later use efficiency of industrial water chillers, resulting in increasing energy consumption.
2. Controlling the purchase cost.
On the premise of guaranteeing chiller’s main energy, it can achieve the goal of reducing cost and satisfying enterprise’s production demand with the least capital by purchasing industrial chiller products at a higher cost performance ratio.
3. Purchase chillers according to the environment used by enterprises.
Water quality and air quality have a certain impact on the operation of water chillers. It is necessary to inform the water quality and air quality of the position of the water chiller manufacturer’s own enterprise in advance.
Verwandte Empfehlungen
-
Ist die Wahl einer Zentrifugalpumpe oder einer volumetrischen Pumpe in einem pharmazeutischen Labor?
2441Leistung: Um den für das pharmazeutische Labor geeigneten Pumpentyp auswählen zu können, ist es notwendig, ein tiefes Verständnis für die Leistung der Pumpe zu haben und die Unterschiede in ihrem spezifischen Funktionsprinzip zu verstehen. Zu diesem Zweck...
Details anzeigen -
How to remove ultra-low temperature refrigerator shell and tube condenser scale?
2115Low-temperature refrigerator ultra-low temperature condenser scale removal In general, we have three methods, namely mechanical descaling, chemical pickling and descaling, and electronic magnetic water separator descaling. Low-temperature refriger...
Details anzeigen -
Tips for Leakage Detection of Low Temperature Freezer
1834Soaking leakage detection The sensibility of soaking leakage detection is higher than bubble test,which is usually applied for small Freon freezer unit. When using it, the equipment prohibited from contacting water in the system should be discharg...
Details anzeigen -
About 60p Refrigerated chiller energy consumption is too large
2484The performance of 60p Refrigerated chiller of different manufacturers is different, and the energy consumption is also different. If the energy consumption of 60p Refrigerated chiller is too large, it is necessary to check in time to see if ther...
Details anzeigen
工業冷水機製造商 LNEYA Taiwan











