How to Deal with the Poor Dissipation of Low Temp Chillers
Low temp chiller products contribute a lot to various industrial production, and at the same time, help to improve the labor efficiency of industrial production. With the development of China’s economy and the improvement of production process requirements, low temp chillers have become an important aspect of the production cooling needs of most enterprises. With the application of low temp chillers in enterprises being more and more extensive, the problems of debugging, maintenance and maintenance of low temp chillers followed. So how to solve the problem of poor heat dissipation of low temp chillers?
Many low temp chiller products, after a period of practical operation, can not dissipate the heat well. At this time, products should be timely maintained. At present, the most effective way to deal with the poor heat dissipation of low temp chillers is that deal with it when the heat dissipation of the condenser is poor, the compressor efficiency is low, the running current is increased and the high pressure of air-cooled chillers rises to 24 kg/cm2.
Most poor heat dissipation problems of low temp chillers can be solved by professional equipment maintenance to adjust the operation of low temp chillers. Sometimes when the heat dissipation is poor, the compressor will escape under the protection of high-voltage switch; the compressor will stop running; the high-pressure overload caused by poor heat dissipation will lead to the fault code or fault indication being displayed. In this case, please check whether the cooling tower circulating water is normal, or shut down and restart to normal operation.
Verwandte Empfehlungen
-
2019 CPHl China | LNEYA W5P22 Ausstellungsgelände&Wunderbar
1992Vom 18. bis 20. Juni 2019 fand die 19. Weltausstellung für pharmazeutische Rohstoffe China - CPhI China 2019 im Shanghai New International Expo Center statt. LNEYA war mit einer Vielzahl von Geräten auf dem Stand W5P22 vertreten, der drei Tage lang ...
Details anzeigen -
Simulation control of temperature change in the cooling and heating temperature control system of th
1676Industrial cooling and heating temperature control system is a temperature control equipment used in the cooling and heating process of reaction kettle in the pharmaceutical and chemical industry. What are the characteristics of lneya's equipment?...
Details anzeigen -
Wie lässt sich das Problem lösen, dass der Stromverbrauch der Kühlkreiselpumpe immer größer wird?
2003Es gibt viele Möglichkeiten für die Zentrifugalpumpe in der Kältemaschine, aber der Ausfall der Zentrifugalpumpe beeinträchtigt die Nutzung der Kältemaschine. Machen Sie sich daher keine Sorgen, wenn die Leistung der Zentrifugalpumpe größer wird, finden Sie die Ursache rechtzeitig heraus und...
Details anzeigen -
Kenntnisse über die Wartung von 12HP (8,9kW) Niedertemperaturkühlern
2235Der Benutzer kann den Bediener über die tägliche Wartung Wissen der 12HP (8.9kW) Niedertemperatur-Kühler nach dem Kauf zu lernen. Es kann nicht nur die Produktqualität des Unternehmens zu verbessern, verbessern die Produktionseffizienz, sondern auch die ...
Details anzeigen