Details der Schutzvorrichtung einer Vorrichtung zur Regelung der Temperatur einer zirkulierenden Flüssigkeit
The circulating pump overload protection function is to cut off the main power of the circulating pump when the circulating liquid temperature adjustment device is too large. Press the green button when resetting; the red button is the stop button, which is used during the test. When frequent protection, please check whether the voltage is under voltage (undervoltage is less than 15%, the power protector is not working), undervoltage is increased into current, forming protection. At this time, a Phillips screwdriver can be used to adjust according to the “△” direction. Current.
Different circulating fluid temperature adjustment devices are equipped with different high and low voltage protectors. The high and low pressure protectors will protect the compressor with reference to the suction and exhaust pressure of the compressor to ensure the normal operation and operating life of the compressor. The high and low voltage protectors are divided into mechanical and electronic high and low voltage protectors. When the high and low voltage protectors are protected, manual reset is required. Press the red highlight button to reset. When the high and low voltage protectors generate protection, manual reset is required. Push the red arrow to reset. The electronic high and low voltage protector is automatically reset.
The circulating fluid temperature adjustment system provides a lot of accessories for equipment protection to ensure the safety and stability of the equipment. The over temperature protection has an independent high temperature temperature limit switch, which can set a relatively large temperature value through this temperature switch (please note) Meet the relatively large operating temperature range of the equipment and the temperature range of the heat transfer oil).
Inspiratory temperature protection with independent compressor suction temperature protector to protect the compressor from excessive suction temperature, ensure that it is within 65 °C (non-recycling liquid temperature adjustment device manufacturer authorization, do not modify, will directly affect the compressor Cooling capacity).
Circulating fluid temperature adjustment device The oil pressure difference protector is generally applied in large equipment. Depending on the equipment, the oil pressure difference protector is different. Press the upper ink green button when resetting. Other types of oil pressure difference protectors are similar. The reset button can be reset by itself. Other protections of the circulating fluid temperature adjustment device include phase protection, phase loss protection, overvoltage and undervoltage protection, leakage protection, and water shutoff protection.
The protection devices of different circulating liquid temperature adjustment devices are different. No matter what brand, the safety devices are more important. We need to pay attention to them. We must carefully check before purchasing to ensure the operation of the equipment.
Verwandte Empfehlungen
-
ISG/TM Motortest Kühlsystem Hochspannungsausfall und Behandlungsmaßnahmen
2406The ISG/TM motor test cooling system is divided into two types in the industry: air-cooled and water-cooled. The working principle is to first inject a certain amount of water into the water tank in the machine, and then pass the ISG/TM motor test...
Details anzeigen -
The Refrigeration Principle of Heating Cooling Circulator
2015Heating cooling circulator is the use of limited refrigerant in the closed refrigeration system, repeatedly refrigerant compression, condensation, expansion, evaporation, constantly in the evaporator heat absorption vaporization, cooling. The heat...
Details anzeigen -
Function of Water Pump of Industrial Water Chiller
2215The water pump is one of the important auxiliary components of the refrigeration system of the industrial water chiller. Many industries will use the industrial water chiller, but many people don't know much about the equipment. This time, lneya r...
Details anzeigen -
Configuration form of circulating heating unit for laboratory
1883The standard model of the circulating heating unit for LNEYA laboratory is: SUNDI, the temperature range is from room temperature to minus 120 degrees Celsius, and the capacity can be divided into 5L, 10L, 20L, 30L, 40L, 50L, 80L, 100L, larger cap...
Details anzeigen