Cooling method for laboratory evaporative instruments in operation
Choosing the right cooling method for an evaporation experiment can have an unimaginable impact on overall system performance, economy, and efficiency. It is necessary to purchase cooling water circulation machine as supporting equipment. When purchasing a suitable cooling water circulator, important factors to consider include: 1. Minimum condensing temperature and corresponding cooling capacity; 2. Circulating pressure; 3. Circulating flow rate; 4. Suitable accessories.
When selecting and setting the temperature of the cooling water cycle machine, it is generally recommended to follow the “Rule of 20”, that is, set a temperature difference of 20°C between the heating pot temperature and the steam temperature, and between the steam temperature and the condenser temperature. The lower the temperature that the cooling water circulation machine can provide, the better the condensation effect. The cooling water cycle machine usually has the maximum cooling capacity at 20°C or normal temperature, that is, the maximum cooling power parameter under ideal conditions, which is often the nominal cooling power marked by the manufacturer.
Our LNEYA cooling water circulator will provide cooling capacity of 20°C and 10°C, and different power supply will also be provided for model selection reference. It adopts international brand compressor, user-friendly design, stable performance and continuous work, flexible and convenient operation, multiple fault alarms and start-up delay protection, and the most important thing is that it is guaranteed to run continuously 24 hours a day.
If you also need temperature control of laboratory instruments, you can contact us for solutions. Email: sales@lneya.com
I hope to hear from you soon.

Verwandte Empfehlungen
-
Die Bedeutung der Auswahl eines Qualitätsherstellers von Kühlern
1579The first is professional operators.Professional refrigeration practitioners are the prerequisite for the maintenance, repair and maintenance of the chiller. If there are no professionals to work on the refrigeration equipment, it will not only c...
Details anzeigen -
Welche Wartungsarbeiten sind bei Glykol-Kaltwassersätzen im täglichen Betrieb erforderlich?
2148Im täglichen Betrieb der Glykolkältemaschine verringert sich die Kühlwirkung, wenn die Wartung nicht durchgeführt wird. Um die Betriebseffizienz zu verbessern, empfehlen wir Ihnen daher, die notwendigen täglichen Wartungsarbeiten durchzuführen. Kältem...
Details anzeigen -
Temperaturbeschreibung der Glykol-Kühlmaschine
1931Für Benutzer und Freunde ist es notwendig, ein tiefes Verständnis der Glykol-Kühlmaschinen vor dem Gebrauch zu haben. Es wird empfohlen, die Temperatur in verschiedenen Geräten wie Kühlsystem, Verdampfungstemperatur, Verflüssigungstemperatur usw. zu kennen...
Details anzeigen -
Recommendations for the use of integrated chip test equipment in the test process
2096From the perspective of the entire semiconductor industry, semiconductors can be divided into R & D, production, and application stages. At different stages, the role of testing is different. Control of test equipment, including test machines,...
Details anzeigen