Aufmerksamkeitspunkte für die tägliche Inspektion von Geräten zur Kontrolle niedriger Temperaturen bei minus 30℃
The low temperature control equipment at minus 30 degrees Celsius is a refrigeration unit or also called a refrigeration unit. The difference from the chiller is the temperature range. It is a commonly used low-temperature equipment in the industry and needs to operate for a long time. So what points should be paid attention to in daily inspection during operation?
1. Power supply part inspection
Before installation, the low temperature control equipment of minus 30 degrees Celsius will make a plan for the surrounding installation environment, circuit and power supply. If the conditions and standards are suitable, the installation will be carried out, and the installation will be re-planned if the conditions are not suitable. After a long period of use, check the power supply part to see if the power supply accessories are damaged, whether the wires inside and outside the equipment are aging, and whether there is damage. If there are problems, check and correct them in time.
2. Refrigerant inspection
The refrigeration effect in the low temperature control equipment of minus 30 degrees Celsius is a more critical part. If the refrigerant leaks, it will affect the refrigeration temperature, fail to achieve the expected refrigeration effect, and affect the overall work progress. While checking the refrigerant of the low temperature control equipment at minus 30 degrees Celsius, check whether the joints of the relevant parts are loose or cracked. If there is a problem, solve it quickly to avoid refrigerant leakage. If a refrigerant leak is found, it needs to be supplemented, and it needs to be added in accordance with relevant standards.
3. Pipeline inspection
The low temperature control equipment of minus 30 degrees Celsius needs to be inspected after a certain period of time to see if there is any leakage. If a leak is found, it needs to be repaired, and then used after checking that there is no leakage.
Verwandte Empfehlungen
-
Analytical description of accessories used in low temperature chiller
1642The low temperature chiller still uses a larger amount of cooling water equipment in our usual refrigeration equipment. When using it, you must first understand the principle of the low-temperature chiller and various accessories to better operate...
Details anzeigen -
Comparison of Three Test Methods for Low Temperature Chamber
22642. Non-heat dissipation test samples and heat dissipation test samples When the temperature of the test sample is stable during the conditional test period, the hottest spot temperature on the surface of the test sample is higher than the ambient...
Details anzeigen -
Automotive new energy battery / motor thermal management performance test
18781. Thermal management physical architecture analysis New energy vehicle thermal management systems typically include engine cooling systems, power device cooling systems for motors, motor controllers, battery pack cooling/heating systems, passenge...
Details anzeigen -
Die folgenden Arbeiten sollten vor der Inbetriebnahme von Industriekühlern durchgeführt werden
19512. Für die Kompressoranlage mit Wassersystem, sorgfältig prüfen, ob das Kühlwassersystem und das Kaltwassersystem Wasser haben, und ob der Wasserdruck normal ist, ob das Rohrleitungssystem von Kühlwasser und Kaltwasser unblockiert ist...
Details anzeigen
工業冷水機製造商 LNEYA Taiwan