Vorsichtsmaßnahmen für die Installation von Spezialkühlern für neue Energieprüfungen
The installation of the special chiller for new energy testing is an important link before operation. The quality of the installation is directly related to the operation and operation status of the special chiller for new energy testing. So, what should be paid attention to in the installation of the special chiller for new energy testing?
If the special chiller for new energy test adopts semi-hermetic or fully-hermetic compressor, an oil separator should be installed, and an appropriate amount of oil should be added to the installed oil separator. When the evaporation temperature is lower than -15 degrees, a gas-liquid should be installed. Separator and add appropriate amount of refrigeration oil. Secondly, the compressor base should be installed with a shock-absorbing rubber seat, and the installation of the special chiller for new energy testing should leave a maintenance space to facilitate the observation of the adjustment of instruments and valves.
The high pressure gauge of the special chiller for new energy testing should be installed at the tee of the liquid storage and filling valve. The overall layout of the special chiller for new energy testing is reasonable and the color is the same. The installation structure of each type of unit should be consistent.
When debugging the special chiller for new energy test, it is necessary to pay attention to measuring the power supply voltage, measuring the resistance value of the three windings of the compressor and the insulation of the motor, checking the opening and closing of each valve of the refrigeration system, and pouring the refrigerant into the storage liquid to the standard charge after evacuation. 70%-80% of the filling volume, and then run the compressor, add air from low pressure to enough volume.
After the special chiller for new energy test is turned on, first listen to whether the sound of the compressor is normal, check whether the condenser and air cooler are running normally, and whether the three-phase current of the compressor is stable. After the special chiller for new energy test cools down smoothly, check the exhaust pressure, suction pressure, exhaust temperature, suction temperature, motor temperature, crankcase temperature, and expansion valve temperature in the refrigeration system, and observe the frosting of the evaporator and expansion valve. , observe the oil level and color change of the oil glass. Check whether the sound of the special chiller for new energy testing is abnormal.
Another point is that the special chiller for new energy testing needs to pay more attention to its maintenance knowledge and carry out a lot of related maintenance work.
Verwandte Empfehlungen
-
Introduction of Industrial Chillers by Industry Manufacturers
2373Industrial chiller is a kind of industrial cooling equipment, which is mainly used to solve the reaction temperature control problems such as machine overheating caused by industrial production. The common reaction kettle in industrial production ...
Details anzeigen -
Beschreibung der Funktionsweise der Hoch- und Tieftemperatur-Schlagprüfkammer
2097Spot hohe und niedrige Temperatur Auswirkungen Prüfkammer, auch bekannt als Drei-Box hohe und niedrige Temperatur Auswirkungen Prüfkammer, hohe und niedrige Temperatur Auswirkungen Prüfkammer ist vor allem der niedrigen Temperatur Speicherkammer, hohe Temperatur Speicherkammer...
Details anzeigen -
Wie wählt man das Schmiermittel für die Spritzgießmaschine aus?
2428Bei der Auswahl des Schmieröls für das Kühlsystem der Spritzgießmaschine muss auf die Art des Kompressors geachtet werden. Der Kompressor hat drei Arten: Kolben-Typ, Schrauben-Typ und Zentrifugal-Typ. Die ersten beiden Arten von Schmieröl sind ...
Details anzeigen -
How to solve the failure of the automatic temperature control system of the reactor?
2154The performance of the automatic temperature control system of the reactor is very important. Once you encounter a failure that cannot be started, you must solve it as soon as possible, otherwise the uncontrollable temperature will affect the reac...
Details anzeigen
工業冷水機製造商 LNEYA Taiwan