Various reactors and materials use PLC temperature control system
The PLC temperature control system is used for the lifting and constant temperature control of glass reactors, metal reactors and bioreactors, especially for heat exothermic control in the reaction process. The heat transfer oil in the jacket of the reactor is heated, and the heat energy is indirectly transferred to the heating kettle in the material, so as to control the heating temperature of the reaction material. The industrial temperature control technology of the equipment has the advantages of high temperature control accuracy, fast heat conduction speed, energy saving, etc. Features.
1. Adopt imported microcomputer or PLC control, pipeline explosion-proof device; air blowing and oil return functions.
2. The oil return temperature indicator has automatic exhaust function when it is started.
3. Heating power switching function.
4. Negative pressure system pressure operation, instant cooling and start function.
5. The isolated electrical control box prolongs the service life of electrical appliances.
6. Realize automatic management; multi-point temperature control unit can be customized, and oil pump horsepower and heating power can be customized.
7. Stainless steel integrated pipeline can reduce pipeline resistance and rust;
8. The PLC temperature control system has the advantages of large temperature control range, good thermal certainty, compact structure, fast temperature rise and fall, and accurate temperature control.
9. The equipment uses the same medium to ensure the system, and there is no danger of water dissolving into the heat transfer oil and causing explosion during the heating process. Multiple heating protections also safeguard the system.
The PLC temperature control system requires users to do regular maintenance work, so as to effectively avoid failures and delay the service life of the equipment, but under the premise that the equipment is of good quality, all the manufacturers and after-sales Teams are also more important.
Our LNEYA PLC temperature control system includes SUNDI series UST series dynamic temperature control system, TCU secondary heat exchange system ZLF and SR series.
Verwandte Empfehlungen
-
Minimum 40 degree refrigerator use precautions
2110The temperature of the lower 40 degree refrigerator is indoor temperature: 5-32 °C, relative humidity 80%/22 °C, the distance from the ground > 10cm, the altitude below 2000m, the safe environment guarantees a smoother operation of the lower 40...
Details anzeigen -
What is the reason for non condensable gas in the condenser of ultra-low temperature cooling water c
2826When the ultra-low temperature cooling water chiller is running, it is necessary to pay attention to the gas state generated by the condenser under a certain temperature and pressure. The existence of these gases affects the operation of the ultra...
Details anzeigen -
Gute Nachrichten! Wuxi Guanya LNEYA Refrigeration bekommt einen neuen Namen
4363According to the `` Notice on Publishing the Evaluation Results of Unicorn and Gazelle Enterprises in the 2019 South Jiangsu National Independent Innovation Demonstration Zone '' issued by Jiangsu Sunan National Independent Innovation Demonstratio...
Details anzeigen -
battery charging test conditions at different ambient temperatures
2412At present, the battery is undoubtedly the most core and critical component in electric vehicles. Therefore, both the OEM and the battery factory need to conduct a comprehensive test of the battery. The characteristics of automotive lithium-ion po...
Details anzeigen
工業冷水機製造商 LNEYA Taiwan














