The entry point for the selection of industrial chillers
Industrial chillers are refrigeration devices that assemble refrigerators, condensers, evaporators, expansion valves, control systems, and switch boxes on a common base or frame. According to the heat rejection method of the unit, it can be divided into water-cooled and air-cooled chillers. The latter adopts heat pump circulation and is welcomed by users. After fully considering the above factors, what should we pay attention to when choosing a chiller?
The main configuration is:
Compressors, electrical components, water pumps, evaporators, condensers, high/low pressure controllers, high/low pressure gauges, LCD thermostats, expansion valves, antifreeze switches, hand valves, and fans. Screw chillers and high-precision constant temperature circulating chillers are trusted by well-known international and domestic vacuum instruments, analytical instruments, and other manufacturers.
Water circulatory system:
First inject a certain amount of water into the water tank of the chiller, cool the water through the chiller refrigeration system, and then send the low-temperature cooling water to the equipment that needs to be cooled by the water pump. The chilled water will take away the heat and increase the temperature before returning to The water tank achieves the cooling effect. The cooling water temperature can be automatically adjusted according to requirements, and long-term use can save water. Therefore, the chiller is a standard environmentally friendly and energy-saving equipment.
When choosing a chiller, you should also pay attention to the following points:
1. Generally, 2 to 4 refrigeration units are appropriate, 2 for small and medium-sized systems, 3 for larger ones, and 4 for extra-large ones. The possibility of mutual backup and switching between units should be considered. Combination schemes with different types and capacities of different units can be used in the same machine room to save energy consumption. At least one unit with a higher degree of automation, better regulation performance, and high efficiency operation under partial load should be selected among the units operating in parallel.
2. The refrigeration coefficient COP of the electric-driven refrigerator is higher than the thermal coefficient. However, each type of unit has its own characteristics and uses its strengths.
3. For the cold source of a large centralized system, it is advisable to choose a chiller with a compact structure, a small footprint, and a compressor, motor, condenser, evaporator, and automatic control components assembled on the same frame. For small systems, direct evaporative compression condensing units should be used.
4. Use domestically produced units as much as possible. my country’s refrigeration equipment industry has developed rapidly in the past ten years, and most of the product performance is close to the international advanced level, especially the small and medium-sized chillers, which are completely comparable to imported products, and have unparalleled advantages in price. Therefore, under the same conditions, domestic chillers should be selected first.
Verwandte Empfehlungen
-
Professionelle Einführung von Leistungsprüfständen mit Motorkühlung
2397Bei der Prüfung von AC- und DC-Motoren und Elektrowerkzeugen werden häufig Prüfgeräte wie Dynamometer verwendet. Der Leistungsprüfstand prüft hauptsächlich das Drehmoment, die Drehzahl und die Ausgangsleistung des Motors. Die Geschwindigkeit des Dynamometers in der Regel Professionelle Einführung von d...
Details anzeigen -
What is the refrigerant of circulating water cooling equipment?
1924Different industries require different refrigeration temperatures for circulating water cooling equipment, so the selected refrigerants are also different. When choosing circulating water cooling equipment, you also need a clear understanding of t...
Details anzeigen -
Wie wird die Batterie beeinflusst, wenn das Brennstoffzellenfahrzeug bei niedrigen Temperaturen kalt startet?
2015At present, the topic of fuel cell vehicles in China is relatively hot. Fuel cell vehicles have the advantages of large market space, high technological status, short hydrogenation time, high battery life, and low pollution. However, at present, f...
Details anzeigen -
Wie wählt man Kältemaschine und Spritzgießmaschine aus?
2021A. First way: The 1HP water-cooled chiller can be equipped with 80 tons locking force injection moulding machine, and the temperature can be controlled at 5-10 degrees. The 1HP water-cooled chiller can be equipped with 100 tons mould-locking force...
Details anzeigen