The selection and maintenance of ultra-low temperature chiller
Today, a customer came to inquire about our need for a small laboratory water chiller. The specific working condition is to reduce the materials in the 20L stainless steel reactor from normal temperature to minus 30 ℃ in more than one hour. This product is too simple for us. The LT-50 series chiller can easily meet all the operating conditions. For model selection, please remember the basic formula: tank volume (or material weight) * material specific heat * temperature difference/second.
Then, maintenance plays a key role in the stable operation of the equipment. After shutdown, start to use the refrigerant recovery device to recover refrigeration.
After the refrigerant is recovered, open the end cover of the water chamber, clean the circulating water system, and replace the oil filter element; After maintenance and installation, vacuum the system with a vacuum pump and maintain the pressure for 24 hours to ensure good airtightness. In the process of filling refrigerant, it is found that the refrigerant cannot be inhaled. It is confirmed that the system is leaking water, and then find the leak point. First, close the inlet and outlet valves at the water side of the evaporator and condenser. After the water inside the machine is drained, open the covers at both ends of the water side of the evaporator and condenser and fully close the outlet valve of the compressor to form a closed space. Refill refrigerant and mark the leakage point. Then, the evaporator and condenser are dried to remove the residual air in the system. Repeat this for many times to ensure that all the air in the system is discharged. Open the bottom corner valve to drain the residual liquid water in the system. Repeat flushing until no residual liquid water is discharged; Finally, the compressor shall be treated by removing the motor first and then drying it, and the withstand voltage test shall be carried out by professionals; Then conduct overall inspection and maintenance, replace damaged parts, and then assemble the compressor as a whole.
The above is about the selection and maintenance of ultra-low temperature chiller. Later, we will talk about the matters needing attention during installation and use.
Verwandte Empfehlungen
-
Motor test chiller compressor causes wear
2088Motor testing chiller oil quality may be one of the main reasons affecting crankshaft wear. If the engine oil is used in the chiller refrigeration system, the engine oil that does not meet the requirements and is of poor quality may cause cranksha...
Details anzeigen -
16. - 18. Juni 2020 | The Automotive Testing Expo Europe-LNEYA
346Die Automotive Testing Expo Europe ist eine Fachmesse für Test-, Bewertungs- und Qualitätstechnik in der Automobilindustrie. Sie ist eine der wichtigsten Veranstaltungen ihrer Art in Europa und präsentiert die neuesten Technologien und Dienstleistungen zur Verbesserung von Qualität, Sicherheit und...
Details anzeigen -
Selection method of 0℃~5℃ freezing liquid for industrial ultra-low temperature chiller
1829As the requirements for process production become higher and higher, industrial ultra-low temperature chillers are required to provide cryogenic liquid below 5 degrees or even more than minus 100 degrees in some chemical process synthesis, reactor...
Details anzeigen -
Wuxi Guanya: Schwerpunkt auf Forschung und Entwicklung von Kühl- und Heizungsanlagen als Beitrag zur Entwicklung neuer Energien
2472On October 17, 2018, the three-day API was held in Nanjing International Expo Center. The exhibition was crowded with people. Wuxi Guanya was a frequent visitor to the API. Wuxi Guanya Constant Temperature Refrigeration Technology Co., Ltd. (herei...
Details anzeigen
工業冷水機製造商 LNEYA Taiwan