Wie man die Lebensdauer eines Glykol-Kühlsystems verlängert?
In order to extend the service life of your glycol chiller in industrial applications, please pay attention to the following points:
1. Use automobile grade antifreeze carefully
Do not use automobile grade or unqualified antifreeze. Because this glycol is not manufactured for industrial applications, it may cause a variety of problems and shorten the service life of your glycol chiller system.
2. Comply with local regulations.
Experts have designed different rules and regulations according to the environmental requirements of this specific area. These are called local regulations, which not only provide safe operation, but also prolong the service life of ethylene glycol chiller system for your industrial application.
3. Fluid filtration and equipment maintenance.
Another secret to prolong the service life of ethylene glycol chiller system is to use fluid filter and carry out fluid maintenance. Operate the equipment as specified in the manufacturer’s manual.
4. Perform all preventive and corrective maintenance.
All planned and unplanned maintenance must be performed to extend the service life of the glycol chiller system· Provide regular maintenance list for all users, such as cleaning, lubrication, dust removal and filter replacement. All inspections are completed in time according to the instructions in the manufacturer’s manual.
5. On time calibration of equipment.
Stickers are attached to all equipment requiring calibration. This shows the calibration date, all of which should be calibrated in time to improve the efficiency of the measuring instrument and prolong the service life of your glycol cooling system.
Verwandte Empfehlungen
-
Detaillierte Beschreibung der Verrohrung von Kühl- und Heizkreislaufanlagen
2118When the refrigeration and heating cycle equipment is in operation, the user will find that whether or not the fully enclosed pipeline affects the overall performance. The LNEYA refrigeration and heating cycle equipment adopts a fully enclosed cyc...
Details anzeigen -
Annäherung an LNEYA 5 Hauptprodukte
3304Industrial Chiller:Industrial Chiller varies from dynamic temp. control systems, heating and cooling machine, water/air cooled chiller and heating circulator.Dynamic temp. control systems.All the industrial chiller differ sometimes considerably i...
Details anzeigen -
Basic structure manual of industrial chiller
2217Industrial chillers are composed of compressors, condensers, evaporators, expansion valves and other accessories. 1. Compressor: In the industrial chiller system, the compressor is the power to ensure refrigeration. The compressor is used to incre...
Details anzeigen -
Effect Of Humidity On Laboratory Chillers
1929The high humidity reduces the insulation strength of the electrical equipment of the chiller in the laboratory. The moisture in the air adheres to the surface of the insulating material to form condensation, which reduces the insulation resistance...
Details anzeigen