Es gibt in der Regel drei Möglichkeiten, die Temperatur von Laborreaktoren zu kontrollieren
1. Manual control: Manually operate the knob on the front of the reactor controller.
2. Control by PC: The PC and the controller are connected by a network cable, and the operation is carried out on the PC.
3. Controlled by thermostat: Silicone oil is heated through the thermostat, and the thermostat naturally has a temperature control function. Although the thermostat heating limit (usually 250°C) is not as high as that of electric heating (can be as high as 400-500°C), the thermostat rises and falls smoothly, and the low temperature can reach -60/-80°C.
Our LNEYA laboratory reactor temperature control system belongs to the third category. However, the temperature control range is from -120 degrees to 350 degrees. It adopts a fully enclosed pipeline design and a high-efficiency plate heat exchanger, which reduces the demand for heat transfer oil, improves the heat utilization rate of the system, and realizes rapid temperature rise and fall. Continuous temperature control can be achieved in the temperature range of minus 90 degrees to 195 degrees and minus 70 degrees to 220 degrees without pressure.
Jacketed glass reactors are popular in current chemical experiments. The supporting temperature control equipment has also become a matter of widespread concern in the industry. It is known that the cooling and heating temperature in the reaction process has an absolute influence on the reaction process and results. The analysis of the temperature control equipment’s ability to increase and decrease the temperature of the material has become the basic basis for choosing chiller. Then the cooling and heating capacity is not only estimated by imagination and experience, but requires scientific analysis and calculation methods, and needs to calculate the required heating power and cooling power according to the heating rate and cooling rate.
When our technicians communicate with customers, they will first understand the requirements of engineering parameters, such as high and low temperature, how long is the temperature control time, etc., so as to calculate the cooling power and heating power of the chiller required, and determine the available chiller. model, to give customers the most complete temperature control solution. If you also have this need, you can contact us.
Verwandte Empfehlungen
-
Solution to High and Low Pressure Fault of Water Cooled Chiller
2482The method to eliminate the shortcomings of high and low pressure of water-cooled chiller has always been a key point and difficulty in the industry, so it is very important to master the solutions to the shortcomings of high and low pressure of w...
Details anzeigen -
Hochdruckversagen eines Tiefkühlschranks aus rostfreiem Stahl
2396At the high speed of the stainless steel cryogenic refrigerator compressor, the temperature rises and the compressor generates high air pressure, which causes the high voltage protection relay to operate. The discharge pressure of the compressor r...
Details anzeigen -
Die Bedeutung der Steuerung des Temperaturzyklus von Heizung und Kühlung bei der Herstellung von API
2353China hat sich zum weltweit größten Absatzmarkt für Wirkstoffe entwickelt. Die meisten der von ausländischen Herstellern benötigten Wirkstoffe und Zwischenprodukte werden in meinem Land gekauft. Der Outsourcing-Prozess für die meisten Präparate, der Produktionsprozess und die...
Details anzeigen -
Attention points for the use of laboratory chiller manufacturers’ equipment
1720Im Labor wird eine breite Palette von Versuchsgeräten verwendet. Wenn die Versuchsgeräte in Betrieb sind, sind sie untrennbar mit dem Hoch-Tief-Kühlkreislauf der Heizungsanlage verbunden. Was ist zu beachten ...
Details anzeigen