Wann sollte man sich für ein TCU-Temperaturkontrollsystem entscheiden?

First of all, we need to know that the reaction kettle generally needs to carry out the necessary temperature control along with the chemical reaction of the material itself. Through the temperature change of the circulating medium in the jacket or coil, the temperature of the material is controlled to achieve the target temperature of the material. For the temperature control of reaction kettles in the chemical and pharmaceutical industries, the selection of temperature control equipment is relatively high. A wide working temperature range is required, and at the same time, different chemical reactions require different temperature curves. The temperature range of the TCU temperature control system developed by LNEYA is from -120°C to 250°C, and the temperature control range is wide. The PID or PLC intelligent control board can achieve percentage temperature control. One host can control multiple units of different sizes and materials. For the reaction kettle, each reaction kettle can be controlled at different temperatures, and a separate material temperature can be set to realize one heating heat exchange host and multiple refrigerant control heat exchange units to control the target temperature of different reaction kettles.
The TCU temperature control system has a unique thermodynamic temperature control system with a series of functions to meet different application requirements. Ensure accurate temperature control and good repeatability of results, short heating and cooling times, and a wide temperature range. Equipped with a new PLC controller, 7-inch color touch screen, the data parameters are clear at a glance, and the real-time temperature change is displayed in a curve. Featuring advanced pump technology to optimize heat transfer, ensure liquid circulation and high flow. Effectively prevent the glass reactor from being damaged due to soft start. Wuxi Guanya TCU temperature control system, temperature control -120~300 degrees, high precision and repeatable temperature control results, fully enclosed pipeline design, no need to replace heat transfer oil; powerful circulating pump, adjustable flow rate, convenient The operating method saves working time and use cost, and can realize continuous work in the state of unmanned monitoring. If there is a fault, it will alarm in time and shut down the system. It is widely used in process industries and production processes in fine chemical, pharmaceutical and other industries.
Verwandte Empfehlungen
-
Wie man die Lebensdauer eines Glykol-Kühlsystems verlängert?
1962Um die Lebensdauer Ihres Glykolkühlers in industriellen Anwendungen zu verlängern, beachten Sie bitte folgende Punkte: 1. Verwenden Sie sorgfältig Frostschutzmittel in Automobilqualität Verwenden Sie kein Frostschutzmittel in Automobilqualität oder ungeeignetes Frostschutzmittel. Da diese Gl...
Details anzeigen -
Small coup to deal with ice blockage of high and low temperature liquid circulating chillers
1618In the operation of high and low temperature liquid circulating chillers, ice blockage is a relatively common fault. Based on the experience of relevant manufacturers, we have specially compiled relevant tips for dealing with ice jams. In the pip...
Details anzeigen -
Trouble shooting method for refrigeration device of air-cooled chiller chemical reaction kettle
1867If air enters into the air-cooled chiller refrigeration unit system of the chemical reaction kettle, the impact will be many. Enter the air circulation system first, the pressure will rise, the heat dissipation effect of the condenser will also be...
Details anzeigen -
Vorteile von Cold Plate Freezer
1886Die Gefriermethode wird hauptsächlich verwendet, wenn das kapazitive Flüssigkristall-Touchpanel von Smartphones und Tablet-Computern Produktionsfehler aufweist, wie z.B. Blasen, Fremdkörper, schwarze Flecken, weiße Flecken, verrutschte..., und zur Wiederherstellung...
Details anzeigen