Ursachen für die verringerte Wärmeübertragungswirkung von vertikalen Ultratiefkühlschränken
If the outer frost layer of the vertical ultra-low temperature refrigerator is too thick or excessively dusty, it may cause the external temperature of the equipment to be mostly lower than 0, resulting in low heat transfer efficiency of the evaporator. Because the vertical ultra-low temperature refrigerator has relatively high humidity, the moisture in the air is easy to frost on the surface of the evaporator, and even freezes, which affects the heat transfer effect of the evaporator. In order to prevent the outer frost layer of the evaporator from being too thick, it needs to be timely Defrost.
Vertical ultra-low temperature refrigerators have two convenient defrosting methods: stop defrost, that is, stop the compressor operation, open the vertical ultra-low temperature refrigerator door, let the temperature rise, and then restart the compressor after the frost layer is automatically melted. Another is the cream. After the contents of the refrigerator are carried out, the surface of the evaporator tube is directly washed with tap water having a relatively high temperature to dissolve or fall off the frost layer. In addition to the excessive frosting, the heat transfer effect of the evaporator is not good. The appearance of the evaporator is too thick due to temporary uncleaning, and the heat transfer efficiency is also significantly reduced.
Vertical ultra-low temperature refrigerators have poor heat insulation and heat preservation effects, which can also lead to poor heat transfer effect, poor heat insulation and heat preservation effect, and poor heat insulation performance because the thickness of the insulation layer of the pipeline is insufficient. Mainly due to the improper selection of the thickness of the insulation layer when designing the vertical ultra-low temperature refrigerator or the poor quality of the insulation data during construction. In the process of construction, the insulation moisture-proof function of the insulation data may be destroyed, resulting in moisture, deformation and even erosion of the insulation layer. The heat insulation capacity is reduced, the loss of the refrigerator’s cooling capacity is increased, and the temperature drop is significantly slowed down.
Another important reason for the large loss of cold is that the vertical ultra-low temperature refrigerator has poor sealing performance, and more hot air invades the equipment from the leak. Generally, if condensation forms on the seal of the vertical ultra-low temperature refrigerator door or the seal of the cold storage wall, it means that the seal is not tight. In addition, frequent switching of the vertical ultra-low temperature refrigerator door or more people into the equipment together will also increase the cooling capacity of the warehouse. The refrigerator door should be prevented from opening as much as possible to prevent large amounts of hot air from entering.
Analysis of these situations, I hope to help the work of my peers, and develop detailed working conditions and maintenance instructions for the vertical ultra-low temperature refrigerator.
Verwandte Empfehlungen
-
Vorteile von Cold Plate Freezer
1886Die Gefriermethode wird hauptsächlich verwendet, wenn das kapazitive Flüssigkristall-Touchpanel von Smartphones und Tablet-Computern Produktionsfehler aufweist, wie z.B. Blasen, Fremdkörper, schwarze Flecken, weiße Flecken, verrutschte..., und zur Wiederherstellung...
Details anzeigen -
How does the Industrial Water Chiller System Work?
2347When using industrial machinery, a cooling system may be required to prevent the machine from overheating. Refrigeration equipment can effectively keep materials in the optimal temperature range, but how does the chiller work? Understanding the wo...
Details anzeigen -
Thermal oil heating system installation and fault analysis
2313When the heat transfer oil heating system device is installed, it is necessary to pay attention to the system to avoid some faults during installation. If a fault occurs, it is necessary to understand the faults related to the heat transfer oil he...
Details anzeigen -
Introduction To The Preparation Of Low Temperature Chiller’ Operation
2193Why do low temperature chiller need to be ready for operation? We must be very clear that only when we are ready to check the low temperature chiller can we run the equipment better, can we run it more efficiently. Before running the low temperatu...
Details anzeigen
工業冷水機製造商 LNEYA Taiwan