Characteristic Analysis of Air Cooled Industrial Chiller
산업용 공냉식 냉각기는 일반적으로 증발기, 압축기 및 콘덴서가 함께 만들어지는 일체형 기계입니다. 약간 고출력 공냉식 산업용 냉각기의 경우 콘덴서 냉각 팬의 열 방출을 고려해야 합니다. 공냉식 냉각기의 열 교환원은 공기이며 특수 팬이 장착되어 있기 때문에 "공냉식 냉각기"라고합니다. 의료, 생물학, 화학, 레이저, 야금, 장비 제조, 전기 도금, 플라스틱 가공 및 기타 산업에서 널리 사용됩니다.
Working principle of air-cooled industrial chiller: different from the traditional water-cooled chiller, the air-cooled chiller does not need the cooling capacity brought by the cooling tower, so it avoids more investment, and is easy to install and manage. Casters are equipped at the bottom of the chiller, which can be moved to cycle between different working areas. This saves a lot of unnecessary fixed investment, and cold water can be discharged directly by connecting power supply and water pipe. According to the design requirements, the outlet water temperature is generally 2 ℃, 0 ℃, -5 ℃ and -15 ℃. When the temperature is below zero, the refrigerant needs to be mixed for heat exchange. The commonly used refrigerant is ethylene glycol.
기존 칠러와 마찬가지로 공냉식 칠러도 고정 된 냉동 사이클 경로를 가지고 있습니다. 원리는 현재 가정용 에어컨과 유사한 역 카르노 효과를 사용하는 것이지만 냉동 루프의 시스템 구조가 개선되어 코프 (에너지 효율 비율)가 매우 높은 경우가 많습니다.
Characteristics of air-cooled industrial chiller:
1. 모든 파이프라인은 기계 파이프라인의 국소 대류를 방지하기 위해 단열 설계가 되어 있습니다.
2. Cooling temperature range: 5 ℃ ~ 35 ℃.
3. 독립 온도 컨트롤러에는 동결 방지 기능이 있습니다.
4. 스테인리스 스틸 단열 물 탱크.
5. 냉매 시스템의 제어 라인 위상 시퀀스 보호 및 고전압 및 저전압 스위치 제어.
6. 친수성 광학 핀 콘덴서는 열 전달 효과가 우수하고 열 방출이 빠릅니다.
7. 컴프레서와 펌프에는 과부하 보호 기능이 제공됩니다.
8. 대용량 쉘 및 튜브 증발기를 채택하여 냉장 효과가 우수하고 고온 환경에 적용 할 수 있습니다.
9. 냉장 효과가 좋은 R404A 냉매를 사용합니다.
10. R507C 친환경 냉매는 옵션입니다.
관련 추천
-
The Following Works Should Be Done Before Starting Industrial Chillers
19512. For the compressor unit with water system, carefully check whether the cooling water system and chilled water system have water, and whether the water pressure is normal, whether the pipeline system of cooling water and chilled water is unblock...
세부 정보 보기 -
Practical application of different compressors in the industrial chiller industry
1758In the current refrigeration industry, the efficiency of the equipment is closely related to temperature. LNEYA tells you that the efficiency of the refrigeration equipment required under control has been improved. Then, the selection of the compr...
세부 정보 보기 -
Refrigeration effect of water-cooled chiller at -15℃
1758The main configurations of water-cooled chillers are: compressors, electrical components, water pumps, evaporators, condensers, high/low pressure controllers, high/low pressure gauges, LCD thermostats, expansion valves, antifreeze switches, hand v...
세부 정보 보기 -
Maintenance knowledge of 12HP (8.9kW) low temperature chiller
2235The user can arrange the operator to learn about the daily maintenance knowledge of the 12HP (8.9kW) low temperature chiller after purchase. It can not only improve the company's product quality, improve production efficiency, but also extend the ...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan