저온 냉각기에 컴프레서 적용
Compressor is an important part of cryogenic refrigeration industry. As far as low temperature chiller is concerned, different brands and types need to be selected when buying compressors. Therefore, when choosing cryogenic refrigeration compressors, we should pay attention to the advantages and disadvantages of each compressor and make better choices.
The cryogenic refrigeration compressors mainly include semi-enclosed piston refrigeration compressor, rotor refrigeration compressor, screw refrigeration compressor, centrifugal refrigeration compressor and so on. The advantages and disadvantages of these cryogenic refrigeration compressors should be dialectically analyzed, and the compressor should be better used and selected.
Semi-hermetic piston refrigeration compressor is widely used in low temperature chiller. The refrigeration equipment of semi-hermetic piston refrigeration compressor has simple internal structure, low requirements for processing materials and processing technology. Compared with other compressors, semi-hermetic piston refrigeration compressor has strong adaptability, wide pressure range and semi-hermetic. The closed piston refrigeration compressor system is relatively simple, and it can meet a wide range of pressure and refrigeration capacity. But at the same time, the semi-closed piston refrigeration compressor also has some defects, such as the shape is larger and the volume is heavier, and has greater noise and vibration. It is difficult for semi-closed piston refrigeration compressor achieve high speed. It has many problems such as vulnerable parts, and inconvenient maintenance.
Rotor refrigeration compressor of 저온 냉각기 is fully enclosed. Small refrigeration equipment is used more, and its refrigeration capacity is not very prominent. Compared with other compressors, it has simple structure, small size, light weight, no suction valve, high speed, small vibration and smooth operation. At the same time, compared with other compressors, the rotor refrigeration compressor system requires higher cleanliness and processing accuracy. The leakage, friction and wear between slider and cylinder wall are larger, and the performance of the compressor decreases obviously. This is also something you need to realize. The other three devices are shown on other pages of our company.
관련 추천
-
반도체 냉장 온도 제어 테이블 쿨러 작동 지침
2168반도체 냉동 온도 제어 스테이션의 변압기 냉각 시스템 제어 시스템의 전원 공급 장치 스위칭은 수입 된 이중 전원 자동 스위칭 장치를 사용합니다. 주요 기능은 자동 스위칭 베팅입니다 ...
세부 정보 보기 -
산업용 냉동 장비의 4방향 밸브를 교체하는 방법은 무엇입니까?
1650The four-way valve of industrial refrigeration equipment needs to be replaced in time after a long period of use, so how to replace it? When replacing industrial refrigeration equipment, you need to first remove the connecting pipe connecting the ...
세부 정보 보기 -
The Application of Industrial Chillers
1747The chiller machine is needed in a lot of industries, basically chemical, medical, pharmaceutical industries are involved, then what industry can Wuxi Lneya chiller meet in the end? It is known that we are one of the top chiller manufacturers. Th...
세부 정보 보기 -
What are the effects of power failure on liquid nitrogen cryogenic cold box?
2258Different industries have different temperature requirements for liquid nitrogen cryogenic cryostats. Of course, there are many types of cryogenic cryostats. The refrigeration methods used in different industries are different. Wuxi Guanya LNEYA u...
세부 정보 보기