The importance of chiller compressors
In the operation of the precision chiller, the compressor is a more important part. If we want to understand the chiller, we have to understand the compressor.
Most precision chiller compressors have a thermal switch inside. The function of this switch is to disconnect the power supply line to the motor of the compressor when the temperature of the compressor exceeds the set value, and it can be turned on until the compressor cools down. The compressor just works. This is the compressor’s built-in protection, the reasons for this and the solution.
The refrigeration system of the precision chiller is short of refrigerant. When the refrigerant is insufficient, the refrigerant returning to the compressor will be overheated, causing the compressor as a whole to heat up, causing the thermal switch to act, resulting in thermal protection of the compressor. Solution: Make up the refrigerant, and the return pipe of the compressor should be cool when it is turned on.
If the condensing pressure of the precision chiller compressor is too high, the cooling water or the high ambient temperature will make the compressor discharge pressure too high, resulting in an excessively high discharge temperature, thus causing the compressor to overheat. Solution: Clean the condenser, or increase the cooling water flow pressure.
The selection is wrong, the selection is small. When the compressor is too small, there will be a small horse-drawn cart, the chiller will never reach the set temperature, and the compressor will continue to work until the compressor is thermally protected. Solution: To re-select a new chiller, there must be an amplification factor to ensure that the chiller can reach the set temperature and stop.
The motor of the compressor of the precision chiller is faulty, and the insulation of the enameled wire is poor, which will cause the compressor current to be too large, and it will also be thermally protected. Solution: Contact the manufacturer to repair the compressor or replace the compressor.
If the compressor of the precision chiller fails, please ask a professional to handle it according to the specific fault treatment, and do not repair it without permission.
관련 추천
-
극저온 공정 냉각 시스템을 사용하여 총 카나비노이드를 추출하는 효율적인 방법
2163Although cannabis plants have been used for medicinal purposes for thousands of years, modern science has identified steroids, flavonoids and more than 100 therapeutically active compounds known as cannabinoids. Due to the significant synergy betw...
세부 정보 보기 -
Introduction of temperature control equipment for cannabis extraction
2070CO2 is a unique solvent because its dissolving power can be changed by simply adjusting the temperature and pressure during the extraction process. When the pressure and temperature of CO2 are higher than 1083 psi and at 88F, CO2 is considered sup...
세부 정보 보기 -
저온 챔버 유지보수 시 주의해야 할 사항
17982. 저온 챔버의 온도와 습도는 기기의 성능에 영향을 미치는 중요한 요소입니다. 기계 부품의 부식을 유발하고 금속 거울의 부드러움을 감소 시키며 오류 또는 성능 저하를 유발할 수 있습니다.
세부 정보 보기 -
What Are The Characteristics Of The Reactor Heating System?
1550Wuxi Guanya LNEYA reactor heating system The liquid circulation of the whole system is closed, the system has an expansion vessel, the expansion vessel and the liquid circulation are adiabatic, do not participate in the liquid circulation, only th...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan