Method for controlling shutdown of water cooled chiller of single reaction kettle
The reaction kettle water cooled chiller has a wide range of accessories and equipment. In actual use, it needs to be provided with regular rest time. In order to maintain the stable performance of the refrigerator during long-term operation, it is necessary for the user to master the method of stopping the operation according to the actual use requirements, and to reduce the excessive wear of the equipment.
1. When it is necessary to shut down, first consider ensuring that the reactor freezer is within the shutdown range before performing all shutdown operations. In order to avoid the generation of high pressure, the user needs to close the suction stop valve to stop the operation of the compressor.
2. After completing the shutdown of the refrigerator compressor, it is necessary to operate the oil pump. Return the slide valve of the freezer to the 0-scale position so that the load reduction reaches zero. At this time, the oil pump will immediately stop all operations.
3. For the reaction kettle water cooled chiller, the operation of the water pump and cooling water tower needs to be stopped in the latter step. After stopping this type of equipment, the entire power supply can be turned off and the entire shutdown process can be completed. Ensure that the reactor water cooled chiller is in the shutdown state.
Precautions for reactor shutdown:
1. If the machine stops for a long time, special treatment is required. Including the condenser and the evaporator, the refrigerant needs to be completely pumped to the condenser, and at the same time all the water sources are discharged to avoid problems such as corrosion.
2. After the shutdown is completed, various accessories need to be carefully tested. The shutdown process is more particular, and the correct shutdown steps can prolong the service life of the equipment.
For the reactor freezer that has been shut down for a long period of time, careful testing is required to ensure that the equipment is kept away from various corrosive substances.
관련 추천
-
Classification and advantages and disadvantages of water-cooled chillers
2323Industrial chillers are divided into air-cooled industrial chillers and water-cooled industrial chillers. Today we will discuss the classification, advantages and disadvantages of water-cooled chillers. Advantages of water-cooled chillers: 1. Inte...
세부 정보 보기 -
전기 자동차 배터리 테스트 드라이버를 접지하는 방법은 무엇인가요?
2000전기 자동차 배터리 테스트가 실행 중이며 액세서리의 작동을 이해하고 드라이브 및 기타 액세서리가 작동 중이어야 합니다. 전기 자동차 배터리 테스트가 A와 B 사이에 분리되지 않은 경우 ...
세부 정보 보기 -
충칭 국제 엑스포 센터 [CIPM] 부스 S3-07-2에서 만나보세요.
1865Exhibition name: National Pharmaceutical Machinery Expo and China International Pharmaceutical Machinery Expo Exhibition time: November 03-05, 2020 Booth number: S3-07-2 Exhibition address: Chongqing International Expo Center
세부 정보 보기 -
Factors affecting the cooling capacity of the chiller of the chemical reactor cooling system
2734There are various types of chillers, such as air-cooled chillers, water-cooled chillers, etc. But no matter what the chiller is, there are some factors that affect the cooling capacity of the chiller. A cooler is an energy-saving device that is co...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan