There are certain differences in the size and performance of high and low temperature fully enclosed circulators from different manufacturers. Users need to pay attention to the placement position when placing them after purchase. If the placement position is not good, it is not conducive to the operation of high and low temperature fully enclosed circulators.
In the installation of high and low temperature fully enclosed circulators, the heat dissipation efficiency of the high and low temperature closed loop circulators should be considered and the maintenance should be easy. The floor of the equipment must be flat and have sufficient strength (3.4 N/m2 or higher). Select a dust. And locations where vibration effects are small.
High and low temperature fully enclosed circulators are to be installed in a dry room with a high and low temperature fully enclosed circulator, and where there is a power supply and sewer nearby, the equipment should be installed in a place with little dust. The wind condition causes no oxygen deficiency to occur even if the refrigerant (fluorohydrocarbon) leaks from the equipment.
Good ventilation should be maintained around the installation of high and low temperature fully enclosed circulators. During operation, the device will radiate heat. If it is air-cooled, it will directly discharge heat through the condensed air. In the case of small room and poor ventilation, the indoor temperature will rise rapidly, causing the machine to stop running and alarm. . Installation of high and low temperature fully enclosed circulators should be kept away from flammable or explosive materials or other substances that may generate high heat.
When placing it, be careful not to let the sun directly project onto the device. When the device is used beyond this range, the safety device will start or the device will stop running. In order to achieve stable performance of the high and low temperature closed loop circulator, the installation room of the high and low temperature closed loop circulator should be air-conditioned to maintain the indoor temperature between 10 ° C and 30 ° C.
The atmospheric environment of the high and low temperature fully enclosed circulator installation site is consistent with the general indoor air-conditioned atmospheric environment. If organic solvents, plasticizers, acids, alkalis or other chemicals are present in the air, the parts or coatings of the equipment may be corroded and destroyed.
The precautions for placing the high and low temperature fully enclosed circulators should be taken seriously by our operators. Read the instruction manual in detail.
관련 추천
-
Dynamic and accurate temperature simulation for test benches in the automotive industry
1724Quality and safety testing are the core elements of the overall development and production process of the automotive industry. With KRY-475 and 455 process cooling circulators, we provide customers with a perfect temperature control solution for p...
세부 정보 보기 -
배터리 테스트 수냉식 냉각기 상식 설명
2330배터리 테스트 수냉식 공기 흡입구 과열이 없는 경우 액체가 포함된 리턴 공기가 있을 수 있으며 습식 스트로크 액체 충격이 발생하여 압축기가 손상될 수도 있습니다. 이 현상을 피하기 위해 어느 정도의 흡입 과열이 다시 ...
세부 정보 보기 -
LNEYA 격리 방폭형 냉각 가열 순환 시스템 SR-35N
1426LNEYA 격리 방폭 냉난방 순환 시스템은 주로 난방용 열전달 매체와 냉방용 냉매를 사용합니다. 그렇다면 격리 냉온수 순환 시스템의 주요 액세서리는 무엇입니까? 어떤 효과가 ...
세부 정보 보기 -
Effect Of Humidity On Laboratory Chillers
1929The high humidity reduces the insulation strength of the electrical equipment of the chiller in the laboratory. The moisture in the air adheres to the surface of the insulating material to form condensation, which reduces the insulation resistance...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan