고온 환경 챔버 판매의 설계 및 테스트 기술
1. Temperature selection
(1) The climatic zones of the region; Whether the product is exposed to the solar radiation environment near the heating device; Surrounding air, solar radiation and ways of heat transfer from heating devices to products; The actual technical state of the product (open or shaded).
(2)Use similar product temperature. Similar products refer to those with similar USES, performance and installation locations, such as upgrading products
2. The conditions of environmental chamber sales
(1) High-temperature storage
Thermostatic storage: after the sample reaches temperature stability (the temperature of internal components, components, modules, components, etc., also reaches stability) in the high-temperature environment, it can be maintained for at least 2 hours, and the longest can be 48 hours. If the storage time is over 48 hours, the temperature stability time will be included.
Cyclic storage: at least 7 cycles (24h for one cycle). If the key material or high temperature sensitive material is affected by high temperature environment, the cycle number should be increased appropriately.
(2) Hot operation in environmental chamber sales
Thermostatic work: after samples reached the stable in high temperature working environment(judgment methods: the differences of the internal heat of samples of the largest feature or key components should be less than 2 ℃ per hour , If the temperature of the internal element (part) cannot be measured, the temperature time shall be determined according to the thermal analysis to ensure that the temperature of the whole sample is stable)keep it at least 2 h, and then let the sample work, and make it on the specified working temperature to achieve stability, began to test the functionality and performance. After the test is completed, the sample will stop working and the air temperature in the box will be adjusted to the standard atmospheric conditions. After reaching the stability under the standard atmospheric conditions, the overall appearance, function and performance will be tested.
3. Temperature monitoring in environmental chambers
When monitoring the test temperature, the position of the temperature sensor should ensure that the influence of thermal diffusion is negligible, and pay attention to avoid the influence of thermal radiation.
관련 추천
-
반도체 레이저 자동 온도 제어 장비 액세서리 결함 솔루션
2159반도체 레이저 자동 온도 제어 압축기 프로스팅, 순환 물 순환 또는 밸브가 열리지 않을 수 있으며, 물 밸브, 모든 파이프 라인을 확인하여 원활하게 단락 파이프 라인을 설치하십시오. 서큘라틴이 ...
세부 정보 보기 -
All analysis of refrigerant changing process of industrial chiller unit
1945Refrigerant is an indispensable part of the refrigeration system of the industrial chiller. During the operation of the industrial refrigeration unit, the refrigerant constantly changes in the industrial refrigeration unit to achieve the cooling e...
세부 정보 보기 -
Introduction of temperature control equipment for cannabis extraction
2070CO2 is a unique solvent because its dissolving power can be changed by simply adjusting the temperature and pressure during the extraction process. When the pressure and temperature of CO2 are higher than 1083 psi and at 88F, CO2 is considered sup...
세부 정보 보기 -
New Energy Car Battery Test Equipment For Battery Description
1769Lead-acid battery raw materials are easy to obtain, the price is relatively low, the high rate discharge performance is good, the temperature performance is good, can work in the environment of -40~+60 °C, suitable for float charging, long service...
세부 정보 보기