전기 자동차 배터리 테스트 드라이버를 접지하는 방법은 무엇인가요?
The electric vehicle battery test is in the running state, and it is necessary to understand the operation of the accessories, and the drive and other accessories are in operation.
If the electric vehicle battery test is not isolated between the AC power source and the drive DC bus (such as a transformer), do not connect the non-isolated port of the DC bus or the ground of the non-isolated signal to the ground, which may result in equipment damage and personal injury. Because the common voltage of the AC is not earth-proof, there may be a high voltage between the DC bus ground and the earth.
In most electric vehicle battery test systems, all common ground and earth are connected together at the signal end. A variety of ground loops generated by grounding are susceptible to noise and generate flow at different reference points.
In order to keep the command reference voltage constant, the signal ground of the driver is connected to the signal ground of the controller, which is also connected to the ground of the external power supply, which will affect the operation of the controller and the driver.
It is difficult to test the grounding of the shield layer of the electric vehicle battery. There are several methods. The correct shielding grounding is at the reference potential point inside the circuit. This point depends on whether the noise source and the receiving are grounded at the same time, or floating. Make sure that the shield is grounded at the same point so that ground current does not flow through the shield.
For the electric vehicle battery test to maintain a stable operating state, it is necessary to understand the operation of the above accessories.
관련 추천
-
리액터 가열 및 냉각 장치의 주요 용도는 무엇인가요?
2042원자로 가열 및 냉각 장치는 고순도 금속, 희귀 물질 정제, 실험실 환경 시뮬레이션, 마그네트론 스퍼터링, 진공 코팅 및 기타 산업에 적합합니다. 대형 극저온 펌프 장치는 냉각 효과를 제공할 수 있습니다.
세부 정보 보기 -
Solution to the inability to cool down the industrial high and low temperature recirculating chiller
2206When the high and low temperature recirculation chiller system is in use, what is the general cause if the high temperature cannot be reduced? How should we deal with such failures? First, let’s analyze the principle and method of cooling. The c...
세부 정보 보기 -
What are the maintenance of glycol chillers in daily operation?
2148In the daily operation of the glycol chiller, if the maintenance is not in place, the cooling effect will be reduced. Therefore, in order to improve the operating efficiency, we recommend that you carry out the necessary daily maintenance. Refrig...
세부 정보 보기 -
난방 순환기 장치의 응축 압력을 낮추는 방법은 무엇인가요?
2194During the operation of the heating circulator unit, the temperature change inside the equipment will cause the condensing pressure to change. Especially in summer when the condensing pressure is too high, the power consumption of the compressor w...
세부 정보 보기