소형 환경 테스트 챔버 압축기는 유지 보수 후주의를 기울여야합니다.
원심식 소규모 환경 테스트 챔버에서 흡입 회수 장치는 일반적으로 독립 시스템이며, 필요한 경우 응축기와 증발기에 연결된 파이프 라인을 닫아 별도의 유지 보수를 할 수 있습니다. 후 ...
After replacing the compressor in the small environmental test chamber, the pumping recovery device generally uses the automatic mode to open, stop and work during the operation of the unit. Therefore, the oil level of the oil separator of the piston compressor should be strictly monitored. Strictly monitor the level of the refrigerant in the recovery condenser. If the liquid level is not visible, the recovery condenser is not effective. Check whether the coolant line and the filter are blocked. If the non-condensable gas removed by the bleed valve contains more refrigerant gas, check if the float valve at the top of the recovery condenser is stuck.
If the venting valve that is automatically vented in the small environmental test chamber does not open the deflation when the specified pressure value is reached, the operation of the suction recovery device should be stopped and the exhaust valve should be overhauled. Frequent activation of the pumping recovery unit indicates that a large amount of air has leaked into the unit. Before the start of the refrigeration unit or during the start-up process, the manual operation of the suction recovery device is generally adopted. The time of each operation is limited by the decrease of the condensing pressure and the heat of the piston compressor motor casing. Generally, the continuous operation time is less than 30 minutes. If the small environmental test chamber is not used for a long time, it can be turned on for a short time to lubricate the compressor part. If the small environmental test chamber does not need to exclude non-condensable gases, the unit should also be operated for 15 to 20 minutes per day or several days.
The maintenance of the small environmental test box is also inevitable. It is recommended to make regular maintenance plans and carry out maintenance in a timely and effective manner.
관련 추천
-
Installation method of heating and cooling temperature control system for automobile motor
2045In chemical and pharmaceutical, chemical laboratories, pilot plants and other industrial processes, the heating and cooling temperature control system is the most used equipment for temperature control in chemical manufacturing, so a highly dynami...
세부 정보 보기 -
How to choose a power battery test evaporator?
2437The corrosion of ferrous metals by salt water is very strong, and its corrosion is more severe when it comes into contact with air. Therefore, as far as the production process permits, closed loops should be used as much as possible. For volatile ...
세부 정보 보기 -
How to Exhaust Air in the Industrial Chiller of Freon System?
1981In the daily operation of industrial chillers, it is easy to appear the situation that the air enters into the refrigeration system. Because the low temperature in the refrigeration system will not condensate the air into liquid, but will affect ...
세부 정보 보기 -
What reactions are microchannel reactors suitable for?
2137In recent years, micro-chemical technology has developed rapidly, and micro-channel reactors have attracted more and more attention. Microchannel reactors are manufactured with the help of special micromachining technology. They have the advantag...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan