Buyers of flash high and low temperature test chiller are increasing day by day. Many people find that the service life is greatly reduced after purchasing. Therefore, operation management and maintenance personnel must have certain professional knowledge and professional skills, so that the service life will be longer.
If the flash high and low temperature test chiller system is properly maintained, it can improve use efficiency, reduce failures, extend the service life of the unit, and greatly reduce operating costs.
1. Regularly clean the air filter of the equipment:
is usually cleaned once every 2 to 3 weeks. Pull out the filter when cleaning, and use a dry soft brush to remove the dust on the filter. It can also be cleaned with water to remove the dust on the filter. After drying, put it into equipment for use.
2. Check the equipment plug and socket:
The user should always check whether the electrical plug of the equipment is in good contact with the socket. If it is found that the power lead or plug is hot when the flash flash high and low temperature test chiller is running, the reason may be that the electrical wiring is too thin or the plug or socket If it is caused by poor contact, measures should be taken to solve it.
3. Long downtime:
Flash Flash high and low temperature test When the chiller needs to be shut down for a long time (such as the seasonal shutdown of the equipment), the equipment should be cleaned.
4. Frequently clean the dust on the panel and cabinet:
Under normal circumstances, we use a dry cloth to wipe. Wipe first, and then wipe off the detergent with a cloth dampened with clean water. Do not use hot water, gasoline, volatile oil and corrosive solvents to clean the panel and casing of the equipment. Avoid using hard-bristled brushes to clean the equipment, so as not to damage the shell, causing paint peeling, fading, etc.
5. Regularly clean the condenser and evaporator coils of the flash high and low temperature test chiller:
Brush and vacuum cleaner can be used. Remind you that when cleaning, the brush and vacuum cleaner should be cleaned in the vertical direction of the coil, and do not clean in the horizontal direction, so as not to damage the fins of the coil.
관련 추천
-
LNEYA의 재순환 냉각기 사용 시 주의사항
2091LNEYA's low temperature recirculating chiller can be used with supporting instruments (such as rotary evaporators, fermentation tanks, chemical reactors, freeze-drying equipment, biopharmaceutical reactors, etc.), with large cooling capacity and f...
세부 정보 보기 -
저온 및 고온 충격 항온항습 테스트 챔버 작동 단계
2036LNEYA 고온 및 저온 충격 항온 항습 테스트 챔버의 적절한 모델을 선택할 때 작동 및 설치 단계에주의를 기울여야합니다. 사용자는 설치 작업을 잘 준비해야 합니다.
세부 정보 보기 -
Why choose LNEYA’s reactor automatic temperature control equipment?
2440With the rapid development of pharmaceutical and chemical industry, the market demand for automatic temperature control equipment for reactors is expanding. The requirements for automatic temperature control equipment for reactors are also rising,...
세부 정보 보기 -
Temperature control unit necessary for Chinese medicine chemical raw material extraction-TCU
2361The production process of traditional Chinese medicine raw materials is relatively complicated: long process, many pipelines, and complicated operations; and most of the preparation raw materials are unstable, such as high environmental parameters...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan