The main purpose of the ethylene glycol chiller for the heating and cooling unit of the reactor
The glycol chiller is suitable for
high-purity metal, rare substance purification, laboratory environment
simulation, magnetron sputtering, vacuum coating and other industries. Large
cryogenic pump units can provide a cooling environment for laboratory instruments.
Cryogenic liquid circulation equipment that adopts mechanical refrigeration. It
has the function of providing cryogenic liquid and cryogenic water bath.

Combined with rotary evaporator, vacuum
freeze-drying box, circulating water multi-purpose vacuum pump, magnetic
stirrer and other instruments, it can perform multi-functional chemical
reaction operations and drug storage at low temperatures. The reactor heating
and cooling device can be used in conjunction with a variety of instruments, with
large cooling capacity, fast cooling speed, low energy consumption, greatly
improving work efficiency; the flow rate of the glycol chiller of the reactor
heating and cooling unit can be adjusted and can be customized. According to
user requirements, there is a reasonable match between low temperature and
cooling capacity, and low temperature and container capacity. Can meet the
actual needs of different users.
The main purpose:
1. It can provide ultra-low temperature and
constant temperature circulating liquid for double-layer glass reactor,
stainless steel reactor, rotary evaporator and other instruments and equipment.
2. Provide a constant temperature
experiment place for glass containers and glass reaction devices.
3. Provide constant temperature test field
source for applications in petrochemical and other industries.
4. It can perform low temperature cooling
and temperature control on the power and light source parts of the electron
microscope.
5. It can perform low temperature cooling
and temperature control on the heating part of industrial machinery.
Points to pay attention to when choosing a
glycol chiller for the heating and cooling unit of the reactor:
1. Choose the circulating pump model
according to the required coolant volume. Of course, the larger the capacity
and the lower the temperature, the higher the price.
2. According to the different temperature
requirements of the experiment, choose a cryopump with the corresponding
temperature control range. The lower the temperature, the higher the price of
the pump, and the low temperature of the heating and cooling device of Wuxi
Guanya reactor can reach -120℃.
3. Whether the test solution is corrosive,
if it is a strong acid/alkali type solution, you need to purchase a
corrosion-resistant reactor heating and cooling device.
Summarize
The above is the main purpose of the
ethylene glycol chiller for the heating and cooling unit of the reactor and the
matters needing attention when purchasing. If you have equipment requirements,
please contact us sales@lneya.com.
관련 추천
-
What should I pay attention to when adding refrigerant to a water-cooled chiller
2157우리 생활에서 누구나 냉방에 매우 익숙하다고 생각합니다. 중앙 공조 및 산업 생산 공정 냉각 산업에서는 소형 수냉식 냉각기가 더 일반적입니다. 이 장치는 압축기로 구성됩니다 ...
세부 정보 보기 -
Is It Necessary to Install A Hot Water Circulation System in Your Home?
1913The heated water circulator is suitable for households where the water heater is far from the outlet. The area of the home is very large, so there is good advantage existing in installing one. After all, it is a test to wait for hot water in winte...
세부 정보 보기 -
Small desktop sealed chiller troubleshooting solution
1846Small desktop sealed chillers will have more or less failures after long-term use, so how can the compressor be solved if there are some faults? LNEYA specializes in the development and production of small desktop sealed chillers with a temperatur...
세부 정보 보기 -
고온 저온 테스트 챔버의 가격 분석
1998속담에 "지불한 만큼 얻는다"는 말이 있습니다. " 고온 저온 테스트 챔버의 가격은 구성의 품질과 관련이 있습니다. 우시 LNEYA의 기술 자체는 귀중합니다. 테스트 챔버 산업에서 고온 저온은 ...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan











