Usage Details of High and Low Temperature Environmental Chambers
The enterprise users must have a certain understanding of the functions of the high and low-temperature environmental chamber after using them for a long time, but something detail of the high and low-temperature environmental chamber may still not be paid attention to, so the technology department of Wuxi LNEYA has specially reorganized the related matters of attention for everyone.
Professional manufacturer of high and low-temperature 환경 챔버 판매
When delivering, the tilted angle of the high and low-temperature environmental chamber should not exceed 30°. When carrying, keep the body of the high and low-temperature environmental chamber vertically, do not place it inversely or horizontally. Besides, dragging the door handle or the condenser are prohibited, otherwise, the equipment may be damaged.
The high and low-temperature environmental chamber should be electrified regularly every month during the lengthy shutdown period, and the power-on time should be more than 1h.
Professional manufacturers of high and low-temperature environmental chamber insist on taking out the test samples after each test and wipe the workroom wall of the environmental chamber to keep the inner box clean.
Cleaning and balance of the circulating blade and condenser fan: Similar to that of the cleaning evaporator, because the working environment of the environmental chamber is different, a lot of small particles like dust will condense on the circulating blade and condenser fan. Hence, they should be cleaned regularly.
The power supply voltage of the high and low-temperature environmental chamber fluctuations, such as repeated power failure. In this case, it is suggested to suspend the use of high and low-temperature environmental chamber and close the power supply to prevent the burning of the compressor. Do not start the compressor immediately after the shutdown of the high and low-temperature environmental chamber. It should be stopped for 2-5 minutes before restarting.
The condenser of the high and low-temperature environmental chamber should be cleaned every three months. The condensing fan should be regularly overhauled and the condenser should be cleaned and dedusted so as to ensure its good ventilation and heat transfer performance.
High and low-temperature environmental chamber should be placed in a well-ventilated position with low humidity and smooth ground, 60 ~ 70 cm of use and maintenance space should be left around.
During the operation of high and low-temperature environmental chamber, the frequency of door opening should be minimized and the spillage of cold air should be reduced.
The usage details of high and low-temperature environmental chamber should be used by enterprise users in daily use.
관련 추천
-
Precautions for small laboratory water chiller before and after startup
2446In the pharmaceutical and chemical industry, small laboratory water chillers are widely used refrigeration equipment, which are often used in various reaction kettles for refrigeration reactions. In order to maintain the stable operation of the eq...
세부 정보 보기 -
Chemical reaction exothermic or endothermic temperature dynamic compensation system
2062In the chemical laboratory, pilot plant and reaction process, temperature control requires the use of dynamic temperature control systems. When controlling the reactor, the exothermic and endothermic reactions must be compensated with high speed a...
세부 정보 보기 -
유리 반응기는 어떻게 선택하나요? 온도 제어 시스템을 맞추는 방법은 무엇인가요?
1929유리 주전자 반응기는 많은 실험실 장비에 필요하며 일반적으로 온도 제어 시스템과 함께 사용됩니다. 화학 및 제약 분야에서 수입 유리 반응기는 기본적으로 필수품이며 냉장 가열 ...
세부 정보 보기 -
What are the reasons for the power consumption of large-size refrigeration units?
1886During the operation of large-size refrigeration units, the cooling capacity and working conditions are the main issues of power consumption, but in order to avoid some unnecessary power consumption, we need to understand clearly. When the scale o...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan