Working characteristics of industrial high temperature and low temperature cooling system
The industrial high-temperature and low-temperature cooling system is mainly used for the monitoring and control of temperature, pressure, flow, liquid level, humidity, pH value and other parameters. It has the characteristics of high control accuracy, stability and reliability. It is widely used in petroleum, chemical industry and medicine to complete sulfuration, nitrification, hydrogenation, alkylation, polymerization, condensation and other processes.
1. The industrial high-temperature and low-temperature cooling system is a process in which the refrigerant transfers and circulates the heat from the low-temperature state to the high-temperature state, so that it can be cooled to the low-temperature environment, so as to maintain the low-temperature state and realize the refrigeration process.
2. The air from the industrial high-temperature and low-temperature cooling system equipment is adiabatically compressed after entering the compressor, and the temperature rises above the ambient temperature; Then it enters the cooler to transfer heat to the cooling water under constant pressure, and the temperature is equal to the ambient temperature; Then it is introduced into an expander for adiabatic expansion, and the temperature is further reduced to below the temperature; After that, it enters the circulating heating cooler equipment, absorbs heat at constant pressure (the absorbed heat is called the cooling capacity), and completes the cycle.
3. After the refrigerant gasifies and absorbs heat from the equipment at constant pressure (at this time, the working medium is usually dry saturated steam or close to dry saturated steam), it enters the compressor for compression in the adiabatic state, the temperature exceeds the ambient temperature, and then enters the condenser for isobaric heat dissipation to the ambient medium.
4. In the condenser, the superheated refrigerant steam is first cooled to the saturation temperature corresponding to the current pressure at the same pressure, and then continues to condense into the saturated liquid state at the same pressure (also isothermal), and enters the throttle valve. At the throttle valve, it is adiabatic throttled for temperature reduction, reduced to the wet saturated steam state corresponding to the initial pressure of the cycle, and then enters the cycle for gasification and heat absorption to complete the cycle.
If you have any questions about temperature control solutions, please contact us sales@lneya.com To obtain technical support, we lneya support program customization, focusing on solving the temperature control of customers’ process.
관련 추천
-
수냉식 배터리 팩의 BMS 테스트를 위한 냉각수 순환기
1850기온이 점차 상승함에 따라 수냉식 배터리 팩 BMS 테스트 냉각수 순환기의 사용량도 점차 정점에 도달합니다. 수냉식 배터리 팩 BMS 테스트 냉각수 순환기의 정격 출력은 ...
세부 정보 보기 -
분리형 난방 냉동 서큘레이터는 비효율성을 어떻게 처리합니까?
1901Heat dissipation is a common problem that causes inefficiencies in isolated heating refrigeration circulators, and it is also a problem that can easily occur. Many isolated heating and refrigeration circulators will have similar problems, so how t...
세부 정보 보기 -
Low temperature refrigeration unit maintenance inspection
2083Low-temperature refrigeration units usually need to do a maintenance. After the maintenance is done, it is not easy to fail, and there will be more markets. If it is not easy to fail, it will not stop working, which is equivalent to saving the com...
세부 정보 보기 -
원자로의 냉각 및 가열 및 사용 원리
2287냉각 및 가열 서큘레이터 온도 조절기는 일반적으로 생화학 기기용 유리 반응기와 함께 사용됩니다. 그들은 현대 정밀 화학, 바이오 의약품, 과학 연구 및 실험 산업에서 널리 사용됩니다. 그들은 집중할 수 있습니다 ...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan











