TCU 통합 온도 제어 장치의 고압 경보가 발생하는 이유
When the TCU integrated temperature control unit is used, it needs to be used according to the instructions in detail. Once problems are encountered, they need to be dealt with in time. Generally speaking, if we encounter a high pressure alarm from the compressor, then we need to carefully analyze various reasons. The reasons include more refrigerant filling, poor condensation effect, electrical failure and many other reasons. So, how should it be handled?
1. There is a lot of refrigerant filling: the main manifestation is that the pressure of suction and exhaust and balancing is too high, and the pressure of the compressor operating current is too large. When in use, it is necessary to ensure its exhaust and balanced pressure according to the rated working conditions, and to ensure that the operating current discharges the refrigerant until the performance is normal.
2. The pipeline filter is blocked or too thin, and the water passing capacity is limited. A suitable filter should be selected and the filter screen should be cleaned regularly; or the pump should be small and not matched with the system.
4. False alarms caused by electrical faults, due to damp, poor contact or damage to the high-voltage protection relay, damp or damaged unit electronic boards, and false alarms caused by communication failures. For this kind of false fault, the fault indicator on the electronic board is often not bright or slightly bright, the manual reset of the high-voltage protection relay is invalid, the running current of the compressor is normal, and the suction and exhaust pressure is also normal.
5. At this time, the expansion valve should be gradually opened, and the opening process should not be too fast to prevent the copper tube in the evaporator from being damaged by too much liquid supply. Wait for a few minutes until the high and low pressure of the unit are balanced. At this time, a lot of white foam can be seen from the sight glass of the evaporator, which means that the oil has entered the evaporator from the condenser.
If the process temperature control unit you are using is the ZLF or SR series of our TCU, you can contact us if you have any questions.
관련 추천
-
Energy storage system requirements for temperature-controlled liquid-cooled unit
2488Energy storage system: It needs to meet the discharge demand for a long time. It is suitable for energy storage on the side of new energy generation, arbitrage of peak-valley price difference on the user side, etc. The future trend is that the pro...
세부 정보 보기 -
/ 난방 및 냉방 온도 조절기의 잘못된 작동을 방지하는 방법은 무엇입니까?
1820When the user is running the heating and cooling thermostat, the operation needs to follow the instructions, so how to avoid inappropriate operations? Excellent design of hot and cold thermostat: The LNEYA heating and cooling thermostat has a mul...
세부 정보 보기 -
Routine maintenance of tcu multi-reactor temperature control equipment
1847TCU multi-reactor temperature control equipment is widely used in research departments such as petroleum, chemical, electronic instruments, physics, chemistry, bioengineering, physical property testing and chemical analysis, colleges and universi...
세부 정보 보기 -
신에너지 차량 품질 테스트를 위한 KRY 시리즈 수냉식 냉각기
1872새로운 에너지 차량 파워트레인 테스트 벤치는 하프샤프트를 통해 전기 구동 어셈블리의 동력 출력단에 직접 연결할 수 있습니다. 프런트 엔드에는 고정밀 토크 센서와 속도 센서가 장착되어있어 높은 정밀도를 제공합니다.
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan