반도체 레이저 자동 온도 제어 장비 액세서리 결함 솔루션
Semiconductor laser automatic temperature control compressor frosting, may be circulating water circulation or valve is not open, check the water valve, all pipelines, to ensure smooth, install short-circuit pipeline. It may be that the circulating water pipe is too small, and the diameter of the circulating water pipe is increased to ensure the normal water circulation.
Semiconductor laser automatic temperature control icing in the circulating water tank may be set too low to correct the set value; there may be no circulating water in the water tank, short circuit water circulation between the chilled water outlet and the inlet; may be the temperature control table out of control Replace the temperature control table with high-voltage faults, poor heat dissipation, the radiator is too dirty, the cleaning radiator can be bad, improve the ventilation conditions, the cooling fan does not work, check whether the fan motor burns out, short-circuit repair or replace the motor; high-pressure engine damage, replacement of high voltage Bad; poor cooling, insufficient refrigerant or pipeline leakage, replenishing refrigerant or repairing after leak detection, vacuuming and replenishing refrigerant, poor heat dissipation, radiator is too dirty, the radiator valve is not opened or opened too small, the radiator is cleaned, Open the valve fully.
Semiconductor laser automatic temperature control pump failure may be semiconductor laser automatic temperature control pump motor coil short, open circuit, repair motor coil or replace the motor, if the pump overload protector automatically jumps, the current limit of the protector is within the allowable range Press the reset button halfway as appropriate.
Semiconductor laser automatic temperature control temperature according to the table temperature display digital up and down jump may be the temperature control table damage, repair or replace the temperature control table, may be poor temperature line contact, repair or replace the temperature line, may be the temperature line and temperature measurement The body is dirty and the temperature measuring body is wiped clean.
The semiconductor laser automatic temperature control compressor failure may be that the compressor coil is short, open circuit, replace the matching compressor, the compressor overload protector automatically trips, and the current limit of the protector is appropriately adjusted and pressed within the allowable range. Reset button.
In order to avoid some faults in the accessories of the semiconductor laser automatic temperature control, it is recommended to maintain a lot of instructions on the automatic temperature control of the semiconductor laser and do the maintenance work.
관련 추천
-
공냉식 냉각기 장비에 대한 자세한 소개
2382LNEYA refrigeration has accumulated over 10 years of cooling supporting application experience. According to different application fields and service conditions, it has developed a variety of types of cooling chillers, including air cooled...
세부 정보 보기 -
저온 냉각기의 주요 기능
2025국내 산업 시장에서 저온 냉각기는 다양한 산업 생산에 적합한 작업 환경을 제공 할 수있는 매우 중요한 생산 보조 장비입니다. 콘덴서는 저온 냉각기의 핵심 부품 중 하나입니다 ...
세부 정보 보기 -
Relevant knowledge of reactor refrigeration equipment
1937The reactor refrigeration equipment is a kind of water cooling equipment, which is a kind of cooling water equipment that can provide constant temperature, constant flow and constant pressure. The working principle of the reactor refrigeration equ...
세부 정보 보기 -
The Advantages Of The Industrial Chiller For Cascade Cryogenic Refrigeration System
2490Cascade cryogenic refrigeration system is a low-temperature refrigeration system which uses more than two refrigerants and combines them with heat exchangers (condenser evaporators) in more than two systems. For binary cascade refrigeration system...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan