Precautions for customers installing Lneya’s cryogenic industrial chillers
One. When installing low-temperature industrial chillers, you need to pay attention to some installation requirements.
1. The cryogenic industrial chiller should be installed directly in a horizontal position, do not install it upside down or diagonally
2. Low-temperature industrial refrigerators generate heat during operation, and should ensure the circulation of cooling air. There should be a certain space around the installation. The generated heat is emitted upwards, so do not install it around heat-resistant equipment.
3. Freezers for low-temperature industry cannot be installed in places with various fiber paper sheets and metal fragments.

The water outlet of the cryogenic industrial chiller should be connected to the water inlet of the supporting instrument, and the water outlet of the instrument should be connected to the water inlet of the cooling circulating water machine.
Second, open the low-temperature industrial chiller, you can see the wiring terminals, do not connect the wrong wire when wiring. (Only high-power low-temperature industrial chillers have power connections)
1. The power supply must be connected to the main wire terminal. If the power supply is connected to other wire terminals by mistake, it will destroy the cryogenic industrial refrigerator. In addition, confirm whether the power supply voltage is within the allowable voltage range;
2. The ground terminal must be well grounded to prevent electric shock or fire accident;
3. Be sure to connect the terminal and the wire with a crimp terminal to ensure the reliability of the connection;
4. After completing the circuit connection, please check whether the connection is correct;
5. With or without wiring;
6. Is there a short circuit between the arrows and the connecting wire or short circuit to ground;
7. If the use temperature is below 5 degrees, please add antifreeze to the circulating fluid.
Low-temperature industrial chillers must be grounded, otherwise electric shock or fire accidents may occur. Wiring should be performed by professionals. Start the work after confirming that the power is off (OFF), otherwise an electric shock may occur.
Three. Operation of cryogenic industrial chillers
1. Check whether the check wiring is correct before starting the operation;
2. Whether the connecting water pipeline is correct and firm;
3. Confirm whether the water tank is filled with water.
Cryogenic industrial chillers are widely used and have certain applications in the pharmaceutical, chemical, petroleum and other industries. In use, you need to know their use knowledge in time to avoid problems.
관련 추천
-
TCU 통합 온도 제어 장치의 고압 경보가 발생하는 이유
1878TCU 통합 온도 제어 장치를 사용할 때는 자세한 지침에 따라 사용해야 합니다. 문제가 발생하면 제때 처리해야 합니다. 일반적으로 고압 경보가 발생하면 ...
세부 정보 보기 -
ISG/TM 모터 테스트 냉각 시스템 고전압 고장 및 처리 조치
2406ISG/TM 모터 테스트 냉각 시스템은 업계에서 공랭식과 수랭식의 두 가지 유형으로 나뉩니다. 작동 원리는 먼저 기계의 물 탱크에 일정량의 물을 주입한 다음 ISG/TM 모터 테스트를 통과하는 것입니다....
세부 정보 보기 -
화학 산업에서 스팀 서큘레이터는 어떤 용도로 사용되나요?
1902화학 산업의 증기 순환기는 제약 및 화학 산업의 온도 제어 장비입니다. 사용자가 작동 할 때 장비를 작동하려면 성능 및 유지 보수 지식을 이해해야합니다.
세부 정보 보기 -
Operation and maintenance of chiller cooling system for alternating high and low temperature tests
2183The operation method of the chiller cooling system for alternating high and low temperature tests: 1. Confirm whether the state of the relevant valves in the unit meets the start-up requirements. 2. Supply power to the electrical control device o...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan