Basic structure manual of industrial chiller
Industrial chillers are composed of compressors, condensers, evaporators, expansion valves and other accessories.
1. 컴프레서: 산업용 냉각기 시스템에서 컴프레서는 냉동을 보장하는 동력입니다. 컴프레서는 시스템에서 냉매의 압력을 높여 냉매가 냉장 시스템에서 순환하여 냉장 목적을 달성할 수 있도록 하는 데 사용됩니다.
2. Condenser: The high temperature and high pressure Freon of the refrigeration system enters the condenser after coming out of the compressor, releases a lot of heat to the cooling medium, and is then cooled and liquefied.
3. Evaporator: When the freon liquid in the refrigeration system enters the expansion valve for throttling and is sent to the evaporator, it belongs to the vaporization process. At this time, it needs to absorb a lot of heat, gradually reduce the valence and mass temperature, and achieve the effect of cooling.
4. Expansion valve: In the flow chart of the refrigerant system of the industrial chiller, we found that there is a small part between the condenser outlet and the evaporator inlet, which is called thermal expansion valve. It is a throttling and decompression component that reduces the condensing pressure of the refrigerant to the evaporating pressure. Therefore, its role in the refrigeration system is essential. It is connected with the refrigeration compressor, evaporator and condenser, also known as the four major components of the refrigeration system.
5. Other accessories: including drying filter and high and low pressure controller. The filter drier is not removable. The internal structure adopts molecular sieve structure, which can remove a small amount of impurities and moisture in the pipeline, thereby purifying the system. High and low pressure controllers play a protective role in the refrigeration system.
관련 추천
-
수냉식 냉각 장치 사용 시 주의사항
1907Cautions To Use The Water Cooling Unit Manufacturers now use recycled water to save costs. However, many manufacturers put circulating water of the whole plant in one water network, which will lead to the problems that the temperature of circulat...
세부 정보 보기 -
The main purpose of the reactor heating and cooling system
2323The reaction kettle heating and cooling system is suitable for high-purity metals, rare substance purification, laboratory environment simulation, magnetron sputtering, vacuum coating and other industries. The large-scale cryogenic pump unit can p...
세부 정보 보기 -
반도체 웨이퍼 온도 제어의 냉동 원리 설명
2416반도체 웨이퍼 온도 제어 냉동 시스템의 작동에서 특정 작동 유체의 상태 전환이 사용되며 필요한 열 Q0은 저온의 열원에서 추출되고 열 Qk는 센 ...
세부 정보 보기 -
Methods for Chiller Manufacturers to Ensure Product Quality
1772Before producing the industrial chiller, the chiller manufacturer will consider the applicable industry, refrigeration capacity, structure, etc., and consider the actual use environment during design and assembly to optimize some functions. In ord...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan