모터 냉각 시스템이 응축 온도에 미치는 영향 테스트
The motor cooling system tests the condenser. Under normal conditions, the first half of the heat pipe is very hot, and its temperature has a slow and slow gradual decline in the balance of power. The heat sensitivity of the second half of the heat pipe is greatly reduced compared with the first half. It is because the refrigerant in the second half of the tube has gradually liquefied, and the condensation temperature and the supercooling temperature have been reached.
When the motor cooling system tests the condenser abnormally, one is that the first half is not too hot, and the second half is close to normal temperature (ambient temperature) because the compressor draws in wet steam refrigerant or the refrigerant amount is insufficient.
When the other is abnormal, the entire motor cooling system tests that the condenser is hot because of excessive refrigerant volume or low ventilation, or high ambient temperature.
In operation, the shell of the shell-and-tube condenser is warmer in the upper half and the lower half is warmer. In the abnormal condition, the entire housing is not too hot, because the refrigerant is not enough, and the other is not. Normally, the entire housing is very hot due to insufficient cooling water or poor heat dissipation (scale in the water pipe). Under normal conditions, the casing condenser is very hot, because the amount of cooling water is too small or the heat dissipation effect is poor.
Motor cooling system test Once the condenser is blocked, it will affect the motor cooling system test cooling effect, so whether it is temperature or blockage, we need regular inspection and maintenance.
관련 추천
-
What are the main equipment needed for industrial chillers?
1674Main equipment of industrial chiller: compressor, condenser, expansion valve, evaporator, chilled water pump, cooling water pump cooling tower (water cooling) Selection: know the required inlet and outlet water temperature, the required cooling ca...
세부 정보 보기 -
How To Solve The Electric Vehicle Motor Test Condensation Is Too High?
2208The condensing pressure of the electric vehicle motor test will increase, the compression function will increase, the cooling capacity will decrease, the cooling coefficient will decrease, and the energy consumption will increase. The reason for t...
세부 정보 보기 -
화학 및 제약 반응기에서 온도 제어 시스템 TCU의 역할
2574의약품 연구 개발 및 화학 실험에서 반응 케틀의 온도 제어는 물론 소규모 실험 생산 및 산업 생산 공정의 온도 제어에는 매우 동적 인 온도 제어가 필요합니다.
세부 정보 보기 -
Operation and Maintenance of Small Water Chiller Units
17842. Air-cooled module internal filter, in order to better filter impurities in the water system, the protective plate heat exchanger is generally more than 40 meshes, that is to say, its filter is more dense and finer than other brands. The advanta...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan