How to judge the operating status of the chemical and pharmaceutical constant temperature control sy
Nowadays, many pharmaceutical and chemical industries use LNEYA’s constant temperature control system. How to judge its operation status during operation?
There should be no noise in the cylinder of the chemical and pharmaceutical thermostatic control system, only the normal and regular sound of the inhalation valve. The condenser cooling water should be sufficient, the water pressure should be above 0.12MPA, and the water temperature should not be too high. There should be no foot heating and frosting on the cylinder wall, and the surface temperature difference should not exceed 15-20 degrees. For refrigerated or low-temperature systems, frosting on the suction pipe can generally reach the suction port; for high-temperature conditions, the suction pipe should not be condensed Frost, condensation is normal.
Chemical and pharmaceutical constant temperature control system Crankcase oil temperature small constant temperature control system does not exceed 70 degrees and not less than 10 degrees. The lubricating oil may have foam, and the exhaust temperature should not be too high. Too high and close to the flash point of domestic refrigeration oil will be detrimental to the equipment. The condensing pressure is not easy to be too high, and the construction capacity of the condensing pressure cold storage is affected by the water source, condensing method and refrigerant. The oil level of the crankcase shall not be lower than 1/2 of the horizontal centerline of the sight glass.

Chemical and pharmaceutical thermostatic control system. The hand-touched horizontal accumulator and oil separator should be cool in the upper part and lower part, and the liquid or oil level at the junction of cold and hot. The safety valve or bypass valve should be cool at the low pressure end, otherwise the high and low pressure series gas. During operation, the evaporating pressure and the suction pressure should be similar, and the exhaust pressure and condensing pressure should be similar to the accumulator pressure.
There should be a temperature difference between the cooling water in and out of the chemical and pharmaceutical constant temperature control system. If there is no or very slight temperature difference, it means that the heat exchanger is dirty and needs to be cleaned. The system should be sealed, and no refrigerant or lubricating oil should be leaked. The shaft seal of the fluorine small constant temperature control system should not drip oil. The temperature of the shaft seal and bearing of the constant temperature control system for chemical and pharmaceutical industries does not exceed 70 degrees. The valve body of the expansion valve is evenly frosted or condensed, but there should be no thick frosting at the inlet. When the fluid passes through the expansion valve, only a dull, small sound can be heard. The pointers of the pressure gauges in the system should be relatively stable and the temperature indication should be correct.
The above conditions related to the chemical and pharmaceutical thermostatic control system can be used to judge the operation status. It is recommended that the operator observe more to determine the faulty sound in time and solve it effectively.
관련 추천
-
저온 챔버의 중요성
1828저온 챔버는 일반적으로 냉장고와 테스트 부품을 분리하고 테스트 부품을 룸 타입으로 만들어 직원이 작업 할 수 있도록하는 대형 극저온 또는 극저온 테스트 장치입니다. 이러한 테스트 룸을 저온 ...
세부 정보 보기 -
차갑게 식히기 위해 선택할 수 있는 장소는 어디인가요?
2276오늘날 과학 기술의 발달로 많은 고객이 고온 및 저온을 사용하여 제품의 품질을 개선하고 제품 비용을 절감하는 데 중점을 둡니다. 그렇다면 모델을 선택할 때 주의해야 할 점은 무엇일까요? 남자...
세부 정보 보기 -
Application of crystallization technology of ultra-low temperature chiller in petroleum industry
1810This article mainly introduces the application of the freezing technology crystallization technology of industrial refrigerators in the oil industry and the principle of freezing crystallization. At present, the separation method using freeze crys...
세부 정보 보기 -
산업용 냉각기의 자세한 작동 지침
2545The installation procedures of water chiller include: 1. During installation, please check whether the machine is damaged and select a suitable place for installation and future maintenance. The site for installing the unit must be the floor o...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan