산업용 공냉식 냉각기 배치 시 주의사항
The quality and use of industrial air cooled chillers are very important. At the same time, the user operation cannot ignore the position placement. Only the correct position placement and high-quality equipment can achieve high-efficiency operating conditions and temperature control results.
Before turning on the power of the industrial air cooled water chiller, check whether the voltage specified on the nameplate is the same as the household voltage. The same can be used. Separate power lines and special sockets must be arranged for the industrial air cooled water chiller system. It cannot be used with other electrical appliances. The same socket, otherwise it will cause bad accidents, the grounding device should be installed, and then the industrial-grade air cooled chiller system should be energized.
Industrial air cooled water chiller systems are placed in places with low humidity. Do not place heavy objects or excessive sundries, especially other electrical appliances, so as not to cause interference.
Place it in a well-ventilated place. The back should be more than 10 cm away from the wall, the top should have a height of more than 30 cm, and there should be no excessive debris around.
Place it on a stable ground, otherwise it will vibrate and make a lot of noise when the compressor is started. This will shorten the service life of Oxue’s industrial air cooled water chiller system for a long time.
Keep away from open flames and high temperatures. Keep it away from heat sources such as stoves and radiators, and avoid direct sunlight. This is conducive to the heat dissipation of industrial-grade air cooled chiller systems.
Don’t ignore these precautions!
관련 추천
-
What are the characteristics of the pressure of industrial water chillers
2222Industrial water chillers are one of the most popular equipment in the machinery and equipment industry. For this reason, the editor of LNEYA specially compiled relevant pressure instructions to help everyone better understand industrial water chi...
세부 정보 보기 -
Solution to oil spill of reactor cooling and heating circulator
1814When we use some reactor cooling and heating circulators, we will find that the system pressure fluctuates up and down as the temperature rises, and the oil tank is overflowing. So what are the reasons for these conditions in the cooling and heat...
세부 정보 보기 -
화학 반응 주전자의 냉장 가열 및 온도 제어 시스템
1846반응 주전자 냉각 및 가열 온도 제어 시스템은 반응 주전자의 다양한 재료의 온도 제어에 일정한 역할을하며 온도 제어 효과는 반응 실험 결과에 영향을 미칩니다. 안정적인 ...
세부 정보 보기 -
How to Choose Water Chiller Units in Small Factories
2198Professional water chiller factory said that the quality of equipment can be seen from the three main components of small water chiller units. The most important one is the compressor, which is the heart of the unit and the most critical component...
세부 정보 보기