What are the reasons for the power consumption of large-size refrigeration units?
During the operation of large-size refrigeration units, the cooling capacity and working conditions are the main issues of power consumption, but in order to avoid some unnecessary power consumption, we need to understand clearly.
When the scale on the tube wall of the condenser of the large-size refrigeration unit reaches 1.5mm, the condensing temperature will increase by 2.8°C compared with the temperature before the scale, and the power consumption will increase by 9.7. The surface of the large-scale refrigeration unit evaporator is covered with a layer of frost, which reduces the heat transfer coefficient, especially when the outer surface of the fin tube is frosted, which not only increases the heat transfer resistance, but also makes the air flow between the fins difficult and reduces The surface heat transfer coefficient and heat dissipation area. When the ambient temperature is lower than 0°C and the temperature difference between the two sides of the evaporator tube group is 10°C, the heat transfer coefficient of the evaporator is about 70 before frosting after one month of operation.

The gas sucked in by the compressor of a large-size refrigeration unit allows a certain degree of superheat, but the superheat is too high, the specific volume of the sucked gas increases, its cold production is reduced, the relative power consumption increases, the compressor is frosted, and the suction is quickly turned off. The valve drastically reduces the cooling capacity and relatively increases the power consumption.
As the evaporation temperature of the large-size refrigeration unit decreases, the compression ratio of the compressor increases, and the energy consumption per unit of cold production increases. When the evaporation temperature drops by 1℃, it will consume 3%-4% more electricity. Therefore, reduce the evaporation temperature difference as much as possible and increase the evaporation temperature, which not only saves power consumption, but also increases the relative humidity of the cold room.
As the condensing temperature of large-size refrigeration units increases, the compression ratio of the compressor increases, and the energy consumption per unit of cold production increases. When the heat exchange surface of the condenser and evaporator of a large refrigeration unit is covered with an oil layer, it will cause the condensation temperature to rise and the evaporation temperature to decrease, resulting in a decrease in cold production and an increase in power consumption. When the air accumulates in the condenser, it will cause the condensing pressure to rise, and the power consumption of the compressor will increase.
If the same large-size refrigeration unit has the same structure and speed, the cooling capacity and power consumption are different if the operating conditions are different. Therefore, the operator will perform the operation after understanding it clearly to avoid the increase in the operating cost of the enterprise.
관련 추천
-
"2021년 원자로 온도 제어 장비 우수 공급업체" 수상
4931미국 포춘지 선정 500대 기업인 코닝이 선정한 '2021 우수 리액터 기술 공급업체'로 선정되었습니다. 2015 년부터 LNEYA는 7 년 연속이 상을 수상했습니다. 따라서 원자로 제조 산업에서 우리는 ...
세부 정보 보기 -
급격한 온도 변화 테스트 챔버 온도 제어 지침
2150급격한 온도 변화 테스트 챔버의 습도 범위 선택은 습도 지수 또는 이슬점 온도 다음에 해당 온도 범위를 표시해야한다는 점에 유의해야합니다. 상대 습도 때문에 ...
세부 정보 보기 -
저온 냉각 윤활유 선택 시 고려 사항
2406극저온 냉각기를 사용할 때는 냉각기의 모든 측면에 대해 확실히 알고 싶을 것입니다. 그러나 모든 사람의 주의가 필요한 것 중 하나는 냉장용 윤활유의 종류가 많은 영향을 미치기 때문에 선택된다는 것입니다.
세부 정보 보기 -
배터리 팩 극한 성능 테스트를 위한 냉각 시뮬레이션 시스템
2124기술의 발달로 순수 전기 자동차가 점점 더 보편화되고 있지만 순수 전기 자동차는 순항 거리, 충전 속도 및 배터리 낭비 후 오염 측면에서 더 나은 솔루션을 얻기가 어렵습니다. 이 메이커는 ...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan