원자로의 냉장 및 난방 시스템 고장에 대한 솔루션
When selecting the pipe material for the reactor refrigeration and heating system, you must pay attention to the connection of the pipe, the choice of the pipe and the material of the pipe. Because the pipe involves cooling and heating, you must remember to pay attention when choosing Oh!
When selecting thermal insulation materials, the temperature range of the refrigeration and heating system of the reactor should be considered first, and flame-retardant materials must be selected. The suitable temperature range of thermal insulation materials should include the temperature range of this equipment. In addition, the thermal insulation material package of the refrigeration and heating system of the reactor should be sufficient, otherwise the equipment control will not achieve the expected effect.
When connecting the refrigeration and heating system of the reactor to the controlled equipment, pay attention to the connection of the pipeline and avoid the error of the interface. Generally, the liquid outlet corresponds to the liquid inlet, and the liquid inlet is connected to the liquid outlet. If it is a water-cooled device , The water outlet corresponds to the water return port, the water inlet corresponds to the water outlet, and the liquid discharge port (used when changing the heat transfer medium) corresponds to the waste liquid recovery collection port.
When selecting pipelines, if improper/damaged hoses and/or hose joints are used, it will cause injury to personnel. Please refer to it carefully when the reactor refrigeration and heating system is equipped with metal insulation hoses and other pipelines. Its pressure-bearing and over-pressure capacity, caliber and suitable temperature range. At this time, the head pressure of the circulating pump inside the equipment needs to be considered. It is recommended that the refrigeration and heating system of the reactor should choose seamless steel pipes and other pipelines with good quality and sufficient caliber as much as possible.
The pipeline connection between the refrigeration and heating system of the reactor and the controlled object should be as short as possible to reduce bending. When the pressure of the circulation pipeline is too high and the pressure of the pipeline is insufficient, it will cause the pipeline and the reactor to burst and high temperature. , The possibility of low-temperature heat transfer medium spraying may cause personnel injuries, burns, frostbite and ignition of combustibles, etc.; pollution, property losses, and even personnel poisoning caused by the loss of reactants.
The vacuum phenomenon of equipment in the refrigeration and heating system of the reactor is one of the main reasons for the excessive noise of the hydraulic pump. When the oil is mixed with air, cavitation is easy to form in its high-pressure area and spread in the form of pressure waves, causing the oil to oscillate and causing the system to produce cavitation noise. The main reasons are: the oil filter of the hydraulic pump, the oil inlet pipe is blocked or the oil viscosity is too high, which can cause the vacuum at the oil inlet of the pump to be too high, causing air to infiltrate. The oil seal on the shaft end of the hydraulic pump and the pilot pump is damaged, or the oil inlet pipe is not well sealed, causing air to enter. The oil level in the oil tank is too low, so that the oil inlet pipe of the hydraulic pump is directly emptied.
When high noise occurs during the operation of the hydraulic pump, the above-mentioned parts should be inspected, and the problem should be dealt with in time. The internal components of the refrigeration and heating system of the reactor are excessively worn, such as the wear and tear of the piston pump cylinder body and the valve plate, the plunger and the plunger hole, etc., which cause serious leakage in the hydraulic pump. When the hydraulic pump outputs high pressure, When the flow rate of oil is small, flow pulsation will be generated, which will cause higher noise.
The hydraulic pump valve plate is also one of the important components that easily cause noise. When the reactor refrigeration and heating system equipment is in use, due to surface wear or sludge deposits on the opening of the unloading tank, the unloading tank will be shortened and the unloading position will be changed, resulting in oil trapping and higher noise.
If the reactor refrigeration and heating system equipment has a noise failure, it needs to be resolved in time, which can reduce equipment failures and improve production efficiency and effectiveness. For other usage content of the equipment, please contact our LNEYA technical engineer to obtain sales@lneya.com
관련 추천
-
Principle analysis of operation of refrigeration heating circulator
2020With the continuous development of technology, more and more refrigeration equipment has appeared in our lives, such as: refrigeration and heating circulators, in fact, they are not ordinary, are remarkable refrigeration equipment. The refrigerati...
세부 정보 보기 -
가열 및 냉동 사이클 장비의 온도 제어 원리와 난이도
1661가열 및 냉동 사이클 장비는 원자로, 일체형 원자로, 반응 탱크 등의 유체 냉동, 가열 및 온도 제어를 위한 장비입니다. 현재 시장에는 더 많은 제조업체가 있습니다. 원자로 또는 반응기가 ...
세부 정보 보기 -
공냉식 냉각기의 주요 적용 분야
2113국내외 산업용 냉각기 시장에서 가장 일반적인 산업용 냉각기 장비는 크게 두 가지 유형으로 나눌 수 있으며, 한 유형은 산업용 공냉식 냉각기, 다른 유형은 산업용 물 공동 냉각기입니다 ...
세부 정보 보기 -
다단 냉동 소형 온도 제어 컴프레서 설명
2077다단 냉동 소형 온도 제어 스테이션 시스템에서 압축기의 기능은 증발기의 냉매 증기를 끌어와 응축기로 배출되는 온도와 압력을 높이는 것입니다. C에서 ...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan