원자로 온도 제어 시스템을 설치하고 사용하는 방법은 무엇인가요?
Many users are going to start the installation after purchasing the reactor temperature control system. What should be paid attention to during installation?
When installing the reaction kettle of the reactor temperature control system, it is necessary to pay attention to whether the reactor is damaged during transportation and installation. The magnetic stirrer on the upper part of the kettle lid should be avoided, and the reaction of the reactor temperature control system should be avoided. The kettle operating room requires good ventilation and meets explosion protection requirements. The reaction kettle equipped with the reactor temperature control system was mounted on a support, and balanced on the four supports to keep the equipment perpendicular to the ground. Anti-static grounding devices should be installed on the flammable and explosive equipment of the reaction medium to eliminate static electricity.
If it is a high-temperature, high-speed magnetic stirrer, the reaction kettle equipped with the reactor temperature control system should be filled with lubricating oil at the bearing oil filling port before use. In the future use, the lubricating oil should be added regularly from the oil filling hole. The reactor equipment for the reactor temperature control system is supplied with cooling water in the outer water jacket of the magnetic stirrer before starting. The lower end is the water inlet and the upper end is the water outlet. A separate cooling water system should be used. The cooling water is not allowed. The cooling coil is then passed through the cooling coil in the kettle to enter the cooling water jacket of the magnetic stirrer.
The control cabinet and frequency converter of the reactor temperature control system equipment should be placed in a separate, electrically controlled workshop with dry and well ventilated. When the stirring speed of the reactor temperature control system equipment is greater than 80r/min, the motor cannot be started directly at the working speed, and the stirring speed should be slowly increased by the inverter. Otherwise, the stirrer resistance is too large, causing the magnetic stirrer to overload and causing the agitation to damage or burn the motor. The reaction kettle of the reactor temperature control system needs to be tested for tightness according to the working pressure. It is kept under inert gas for 15~30 minutes to check whether the whole equipment is leaking. If there is no leakage, it can be put into production.
When using the reactor temperature control system, it is necessary to pay attention to the switch is not suitable too much, so as not to damage the overall performance of the reactor temperature control system and the life of the fitting.
관련 추천
-
배터리 테스트 온도 시뮬레이션 시스템이 전기/하이브리드 차량 냉각 테스트에 미치는 영향
2128전기 자동차 산업에서 배터리는 자동차의 중요한 부품이며, 그 성능은 하이브리드/전기 자동차의 성능에 직접적인 영향을 미칩니다. 이러한 이유로 시장의 관련 제조업체는 배터리 쿠 ...
세부 정보 보기 -
The Refrigeration System of a Cryogenic Chiller
2023In recent years, cryogenic chiller products are more and more common in the domestic industrial market. Many industrial productions need more help from cryogenic chiller products to achieve the ideal low-temperature environment. Therefore, cryogen...
세부 정보 보기 -
레이저 냉각기를 선택하는 방법은?
2436레이저는 자극 방사선에 의한 빛 증폭의 약어입니다. 광학 물질(예: 유리, 크리스탈 또는 가스)의 원자에 있는 전자가 전류의 에너지를 흡수하면 레이저가 생성됩니다. 증가된 에너지는 ...
세부 정보 보기 -
What Are The Characteristics Of Refrigeration Of Industrial Chillers?
2124If there is a high temperature difference between the inlet and outlet water, then a large external tank will be used to store cold water. In this case, the cooling water will not be directly from the cooler application. Deep into the outside of t...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan











