Introduction to the quality and configuration of industrial refrigeration and heating circulators
With the development and progress of society, industrial refrigeration and heating circulators are used more in the industry, and the technological level is becoming more and more complex. So, what should users pay attention to after purchasing this equipment?
1. In order to consume electricity, many companies will cut off the power after the experiment. According to the technical staff, we explained that if the industrial refrigeration and heating circulator is powered off in winter, the inner tank is prone to aging, thereby reducing the equipment’s performance. service life.
2. During normal use, when the temperature in the box drops to a certain set value, the thermostat will cut off the power by itself. At this time, the pressure of the refrigerant is already very low, and the compressor is relatively small compared to the load of the motor. , the motor is easy to start normally, if the power is forced to be cut off, the power will be turned on immediately when the refrigeration has a relatively high pressure. Although the high voltage will cause the motor to be overloaded, it is easy to burn the motor due to excessive current. Therefore, industrial refrigeration and heating circulators cannot be powered off at will.
3. The industrial refrigeration and heating circulator that is in a power-off state cannot be powered on at will, especially for newly purchased equipment, it must be placed for one to two hours before it can be powered on.
4. There is a certain space between the inner tank and the outer shell. The electric heating tube is used to provide heat to transfer the heat to the heat-conducting oil medium, and then the heat is transferred to the inner tank of the reactor through the heat-conducting oil bath, and the material medium in contact with the inner tank passes through the steel plate. The heat is used to increase the temperature, and the temperature required for the reaction of the material is slowly reached.
5. The electric heating tube is generally 220v/380v voltage, and the 220v electric heating tube must be three in a group, connected to form three power supply requirements (general industrial production does not use direct single-phase wiring), through three in a group, you can According to the total number of electric heating pipes required, multiple groups are formed.
There are certain differences in the quality and configuration of industrial refrigeration and heating circulators from different manufacturers. Users can judge and use them according to the reaction kettle heating and temperature control machine they purchased.
관련 추천
-
유리 반응기는 어떻게 선택하나요? 온도 제어 시스템을 맞추는 방법은 무엇인가요?
1929유리 주전자 반응기는 많은 실험실 장비에 필요하며 일반적으로 온도 제어 시스템과 함께 사용됩니다. 화학 및 제약 분야에서 수입 유리 반응기는 기본적으로 필수품이며 냉장 가열 ...
세부 정보 보기 -
최적의 냉각기 솔루션을 선택하는 방법은?
1845Choosing a water chiller is like finding a "target" for an enterprise's production equipment. It must not only be "like-minded", but also "be well-matched". The one that suits you is the best. If the choice is not good, either the cooling effect ...
세부 정보 보기 -
Automotive new energy battery / motor thermal management performance test
18781. Thermal management physical architecture analysis New energy vehicle thermal management systems typically include engine cooling systems, power device cooling systems for motors, motor controllers, battery pack cooling/heating systems, passenge...
세부 정보 보기 -
아케마 2018에 참가하는 LNEYA
14132018년 6월 11일부터 15일까지 독일 프랑크푸르트 암 마인에서 열리는 공정 산업을 위한 세계 포럼 및 선도 전시회인 ACHEMA에 참가할 예정입니다(자세한 정보는 곧 공개될 예정입니다),
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan