Low temperature refrigeration unit maintenance inspection
Low-temperature refrigeration units usually need to do a maintenance. After the maintenance is done, it is not easy to fail, and there will be more markets. If it is not easy to fail, it will not stop working, which is equivalent to saving the company’s cost. It should be noted that the low-temperature refrigeration unit is maintained. It is very important to lubricate the industrial machinery at ordinary times, because it is always in operation, and the parts that run frequently must be lubricated regularly. If lubrication is not added, the friction will be large. The parts are worn out, so they should be observed and inspected regularly.
Different configurations use different lubricants:
If a problem with the low-temperature refrigeration unit is found, it should be replaced immediately. Different configurations require different lubricating oil. Remember to use special lubricating oil, don’t use a kind of lubricating oil casually. If you use the wrong lubricating oil, the effect of lubricating oil will not be good. It is also possible that the lubricating oil will fall directly from the top when the lubricating oil is just applied. What a role.
Regularly replace the filter drier:
The filter drier should also be replaced. The filter drier is a very important component to ensure the normal circulation of the refrigerant. Water and refrigerant are incompatible with each other. If the system contains water, this will greatly affect the low-temperature freezing The operating efficiency of the unit, so it is very important to keep the system dry. If you want the internal dry, you need to replace the filter element inside the filter regularly.
Regularly check the pipeline for scale:
One of the usual maintenance of low-temperature refrigeration units should also pay attention to check whether the pipeline has deposited scale? If there is too much scale, it will significantly affect the heat transfer. The contact surface of cooling water will also shrink, the quantity will decrease, and the condensing pressure will increase. Usually, it is necessary to use tap water to use a water-cooled chiller. The quality of tap water in different regions of our country is different. Some are alkaline and some are alkaline. If the sex is small, some have more impurities, some have less impurities, and if there are more impurities for a long time, some very obvious scales will easily appear, and the effects we have just mentioned will appear.
To Sum Up
We need to carry out regular maintenance and inspection of the equipment, which can not only improve the efficiency of the machine but also save costs.
관련 추천
-
영하 30℃에서 저온 제어 장비의 일일 점검 시 주의 사항
1901영하 30도의 저온 제어 장비는 냉동 장치 또는 냉장 장치라고도 합니다. 냉각기와의 차이점은 온도 범위입니다. 그것은 산업에서 일반적으로 사용되는 저온 장비입니다 ...
세부 정보 보기 -
순환식 쿨러의 사용은 어떤 측면에서 고려해야 하나요?
1676Circulating coolers are a popular choice for temperature-critical applications because they provide stable temperature control, constant flow and constant pressure control. Many process heating systems require cooling and heating. For example, man...
세부 정보 보기 -
냉각 및 난방 오일 욕조를 사용할 때 주의해야 할 사항은 무엇인가요?
1771고온 및 저온 제어에서 냉각 및 가열 오일 배스는 더 중요한 장비 중 하나입니다. 장치를 작동할 때 사용자가 주의해야 할 점은 무엇일까요? 냉각 및 가열 오일 배스 장비는 깨끗하게 유지해야합니다 ...
세부 정보 보기 -
화학 및 제약 반응기에서 온도 제어 시스템 TCU의 역할
2574의약품 연구 개발 및 화학 실험에서 반응 케틀의 온도 제어는 물론 소규모 실험 생산 및 산업 생산 공정의 온도 제어에는 매우 동적 인 온도 제어가 필요합니다.
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan











