The safety of heat transfer oil in water-cooled chillers
In order to achieve better operating efficiency, water-cooled chillers need to choose branded heat transfer oil, but you need to pay attention to safe placement, a little carelessness will cause adverse effects.
Although the heat transfer oil of the water-cooled chiller has a higher boiling point, it is still a flammable liquid. Therefore, you should pay attention to safety when using it. Improper use may cause fire. The cause of the fire is caused by leakage. There are four main types of leakage and fire:
A. Fire in the heat preservation area.
Common misfire types in organic heat transfer oil systems. The heat transfer oil leaks at the instrument connection and penetrates into the heat preservation area. Then, in the presence of air, the circulating liquid and pipe heat will heat the heat conduction oil and gradually oxidize the liquid, causing the heat preservation area to be ignited and cause a fire.
B. Fire caused by pipeline leakage or burst.
The leakage or burst of the pipeline caused the heat transfer oil to flow into the hot gas flame zone and cause a fire.
C. The flash point causes a fire.
The factors that cause the flash point fire are higher than the low flash point temperature of the heat transfer oil, and there are heat transfer oil, air and fire sources at the same time.
D. Fire caused by process raw materials:
The main reason is that the heat-conducting oil leaks into the heating system, and its process raw materials are easily oxidized and have oxidizing substances, which causes a fire.
In addition to the above four types of fires, more attention should be paid to the use of gas-phase systems. If a large amount of heat transfer oil vapor leaks, aerosol mist may be formed. This mist may cause explosion and combustion in the air when exposed to an open flame.
Therefore, the heat transfer oil of water-cooled chillers is related to its operating efficiency and safety, so it is necessary to do a good job in the repair and maintenance of the hot oil system to prevent the leakage of the heat transfer oil.
관련 추천
-
What are the applications of Industrial temperature control machine chillers?
2336Industrial temperature control machine chillers are divided into oil-cooled and water-cooled according to the temperature and medium. The medium used is different for different temperatures, water can be selected for normal temperature, heat tra...
세부 정보 보기 -
What is the temperature control method of the reactor?
1802The reaction kettle used for temperature control has a large capacity and a thick wall, so it is a controlled object with a large heat capacity and a long pure lag time. As the reaction progresses, the heat transfer coefficient of each heat transf...
세부 정보 보기 -
공식 발표! 2018 API China 공식 개막
1981Official announcement! 2018 API China On October 17th, the Nanjing International Expo Center officially kicked off~ Wuxi Guanya carries popular products: Refrigeration heating temperature control system, TCU, refrigeration heating circulator and o...
세부 정보 보기 -
What are the maintenance of glycol chillers in daily operation?
2148In the daily operation of the glycol chiller, if the maintenance is not in place, the cooling effect will be reduced. Therefore, in order to improve the operating efficiency, we recommend that you carry out the necessary daily maintenance. Refrig...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan