LNEYA semiconductor refrigeration unit common fault description
If a high-voltage alarm occurs in the semiconductor refrigeration unit, it is necessary to check whether the external piping is blocked or dirty. Clean and remove in time. If it is an air-cooled semiconductor refrigeration device, it is necessary to check the space ventilation condition of the semiconductor refrigeration device. If the space is small and the ventilation is not good, it is easy to cause a high-pressure alarm. In addition, if the compressor discharge pressure is too high, pressure relief is required. Turn on the pressure relief valve and put some gas on it.
Leakage refrigerant is one of the more common faults in semiconductor refrigeration equipment. There are many causes of refrigerant leakage in refrigeration systems of semiconductor refrigeration equipment, mainly in the welding area, which has its own manufacturing problems and is caused by customers. Leaking the refrigerant directly causes the semiconductor refrigeration unit to be unable to cool, and it is necessary to check for leaks. Check that it is leaking refrigerant in that place, and then make it up.
The low-temperature alarm and leakage refrigerant of the semiconductor refrigeration device are closely related. The first thing to do is to check whether the refrigerant is leaking. Most of the low-voltage conditions are caused by the leakage of the refrigerant in the semiconductor refrigeration device. Therefore, it is necessary to check the refrigerant and still need to check for leaks. If the compressor of the semiconductor refrigeration unit does not work, it is necessary to check whether the water pump of the semiconductor refrigeration device is good or bad. If the water pump is good, it is necessary to see if the water in the semiconductor refrigeration device tank can be replenished, and then check the current.
Since the semiconductor industry has certain requirements for the operation efficiency of the semiconductor refrigeration device, it is better for the semiconductor refrigeration device to avoid these faults as much as possible.
관련 추천
-
Cooling system of liquid-cooled energy storage cabinet-chiller
1976With the development of new energy technology, the application of containerized energy storage systems in new energy, photovoltaic, and electric energy stations has increased. If the temperature of the energy storage battery pack is not well contr...
세부 정보 보기 -
Classification and Application of Industrial Water Chillers
2236In lots of industrial production processes, it is difficult to obtain high efficient industrial production efficiency if there is no industrial water chiller to provide a low temperature production environment. Therefore, industrial water chil...
세부 정보 보기 -
유리 반응기 온도 제어를 지원하는 냉각 및 가열 온도 제어 시스템
2116우리나라의 화학 산업은 빠르게 발전해 왔으며 많은 기업들이 안정적인 발전을 가속화했습니다. 화학 산업에서 냉동 가열 온도 제어 시스템은 유리 원자로와 일치하여 반응을 제어합니다.
세부 정보 보기 -
The Instruction Of Ultra Low Temperature Freezer Minus 80 Degrees
2086The machine must be tested before usage (or before it is energized again) in the following conditions: when ultra low temperature freezer is first used in ultra low temperature freezer minus 80 degrees, or after the ultra low temperature freezer i...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan