ZLF/SR 시리즈 원자로 온도 제어 장비의 작동 시 주의사항
The temperature control equipment of the reaction kettle adopts the PID control method, which greatly improves the temperature control accuracy of the whole machine. The microcomputer for cooling or heating will automatically switch to work according to the temperature setting, which simplifies the operation procedure and avoids the damage to the machine due to misoperation.
1. The fully enclosed pipeline system reduces the oxidation of heat transfer oil and is equipped with a unique cooling function. The heat transfer oil will inevitably produce oil mist when it works at high temperature. If it is not cooled in time, its service life will be greatly shortened. With this cooling function not only prolongs the service life of the oil but also reduces the flow of circulating pressure.
2. At present, it is widely used in the pharmaceutical and chemical industry, and the specific size can be distinguished according to the model. Like general equipment, it also needs to be carefully maintained during use.
3. If it is not running, if only the cooling water tower is needed for cooling, it is necessary to turn off the water source for the temperature control of the TCU reactor, and dispose of the water in the internal components and pipes of the TCU reactor temperature control, and pay attention to avoid the temperature control of the TCU reactor. The residual liquid inside will corrode the internal components of the equipment. At the same time, you need to pay attention to the temperature of the equipment. Do not place it at too low temperature to avoid frost heaving copper pipes at low temperatures.
4. It is necessary to check whether each part inside the temperature control equipment of the reactor is worn or not. If any wear is found, please replace the parts in time. In addition, the fan of the reactor temperature control equipment should always be kept in a clean state to avoid dust blockage.
The above content is about the operation precautions of LNEYA’s TCU multi-reactor temperature control equipment. If you are interested and would like a quote, you can contact sales@lneya.com.
관련 추천
-
How important is the insulation of the chiller?
2491Answer: For the chiller, if it is operated at high temperature, a large amount of cold air in the industrial chiller may be severely lost. After the sealing effect of the use environment, through timely and effective heat preservation, the operati...
세부 정보 보기 -
Description of requirements for installation of glycol chiller
1940Generally, after purchasing the equipment with the glycol chiller manufacturer, the installation manual will be distributed to the user together. So, what should be paid attention to when installing the glycol chiller? In summer, glycol chillers...
세부 정보 보기 -
고온 및 저온 급격한 온도 변화 테스트 챔버 공통 결함
2016고온 및 저온 급격한 온도 변화 테스트 챔버의 고온 테스트에서 온도 변화가 테스트 온도 값에 도달하지 않으면이 경우 전기 시스템을 검사하고 결함을 제거 할 수 있습니다 ...
세부 정보 보기 -
Failure Analysis of Ultra Low Temperature Chiller Supporting Distillation Equipment
2479Once the freezer used in the matching distillation equipment fails, we need to solve it in a timely and effective manner to avoid affecting the operation of the entire experiment. In the pharmaceutical, chemical and other industries, low temperatu...